Kinetic analysis of 125I-iodorotenone as a deposited myocardial flow tracer: comparison with 99mTc-sestamibi.

نویسندگان

  • R C Marshall
  • P Powers-Risius
  • B W Reutter
  • S E Taylor
  • H F VanBrocklin
  • R H Huesman
  • T F Budinger
چکیده

UNLABELLED The goal of this investigation was to assess the accuracy of 7'-Z-[125I]iodorotenone (125I-iodorotenone) as a new deposited myocardial flow tracer and compare the results with those for 99mTc-sestamibi. METHODS The kinetics of these two flow tracers were evaluated in 25 isolated, erythrocyte- and albumin-perfused rabbit hearts over a flow range relevant to patients. The two flow tracers and a vascular reference tracer (131I-albumin) were introduced simultaneously as a compact bolus through a port just above the aortic cannula in the absence of tracer recirculation. Myocardial extraction, retention, washout, and uptake parameters were computed from the venous outflow curves using the multiple-indicator dilution technique and spectral analysis. RESULTS The extraction of 125I-iodorotenone was much higher than the extraction of 99mTc-sestamibi (0.84 +/- 0.05 vs. 0.48 +/- 0.10, respectively, P < 0.001). 125I-iodorotenone extraction was also less affected by flow than was 99mTc-sestamibi (P < 0.001). Net retention of 125I-iodorotenone was significantly greater than 99mTc-sestamibi net retention at 1 min (0.77 +/- 0.08 vs. 0.41 +/- 0.11, respectively, P < 0.001) and 26 min (0.46 +/- 0.13 vs. 0.27 +/- 0.11, respectively, P < 0.001) after tracer injection. Flow had less effect on 125I-iodorotenone net retention than on 99mTc-sestamibi net retention 1 min after tracer injection (P < 0.04). However, at 26 min, flow had an equivalent effect on the retention of both flow tracers (P < 0.4). The relationship between 125I-iodorotenone and 99mTc-sestamibi washout was complex and depended on elapsed time after isotope introduction and perfusion rate. Reflecting the favorable extraction and retention characteristics of 125I-iodorotenone, both its maximum myocardial uptake and its 26-min uptake were more closely related to flow than were those of 99mTc-sestamibi (P < 0.001 for both comparisons). CONCLUSION The extraction and retention of 125I-iodorotenone were greater than those of 99mTc-sestamibi, making 125I-iodorotenone the superior flow tracer in the isolated rabbit heart.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Localization of radiolabeled cardiac myosin-specific antibody in myocardial infarcts. Comparison with technetium-99m stannous pyrophosphate.

The myocardial uptake of radioiodinated (Fab')2 fragments of antimyosin antibody [125I-(Fab')2] was compared with simultaneously administered 99mTc-pyrophosphate (Tc-PYP) in dogs undergoing coronary occlusion for 24 (N=6) or 72 hours (N=5). Relative concentrations of both agents in normal and infarcted myocardium were related to regional blood flow as determined by distribution of 55Sr-labeled ...

متن کامل

Determination of Uterus Absorbed Dose by Patients following Myocardial Perfusion Scan using TLD and Conjugate View Methods

Introduction: The determination of patient’s absorbed dose is the first step of radiation protection which depends on the quantification of organ activity in nuclear medicine. The aim of the present study was to determine the absorbed dose by patient’s uterus following myocardial perfusion scan with 99mTC-sestamibi using Theroluminescnce dosimetry (TLD) and conjugate-view metho...

متن کامل

Myocardial technetium-99m-tetrofosmin and technetium-99m-sestamibi kinetics in normal subjects and patients with coronary artery disease.

UNLABELLED This study was designed to compare the tracer kinetics between 99mTc-sestamibi and 99mTc-tetrofosmin in a heterogeneous group of 24 patients admitted for routine perfusion imaging. METHODS Twelve patients were studied with 99mTc-tetrofosmin and 12 with 99mTc-sestamibi. In each group, six patients had a low likelihood for coronary artery disease, and six patients had angiographicall...

متن کامل

99mTc-Tetrofosmin in Rats

99mTc-[bis (dimethoxypropylphosphinoethyl)-ethoxyethylamine (PNP5)]-[bis (N-ethoxyethyl)-dithiocarbamato (DBODC)] nitride (N-PNP5-DBODC or N-DBODC5) is a new monocationic myocardial perfusion tracer. We sought to compare the myocardial uptake and clearance kinetics and organ biodistribution of 99mTc-N-DBODC5 with 99mTc-sestamibi and 99mTc-tetrofosmin. Methods: Seventy-five anesthetized Sprague–...

متن کامل

Persistent sub-diaphragmatic activity on the myocardial perfusion scan with 99mTc-Sestamibi

We present a female patient with atypical chest pain who was referred to our department for ischemia evaluation. 99mTc-MIBI myocardial perfusion scan with dipyridamole stress was performed. Sub-diaphragmatic activity in the hepatic tissue and then in the bowel loops caused severe overlap on the inferior wall even on consecutive delayed images. Dipyridamole stress was repeated for the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 42 2  شماره 

صفحات  -