Intraoperative Myelography in Cervical Multilevel Stenosis Using 3D Rotational Fluoroscopy: Assessment of Feasibility and Image Quality
نویسندگان
چکیده
Background. Intraoperative myelography has been reported for decompression control in multilevel lumbar disease. Cervical myelography is technically more challenging. Modern 3D fluoroscopy may provide a new opportunity supplying multiplanar images. This study was performed to determine the feasibility and image quality of intraoperative cervical myelography using a 3D fluoroscope. Methods. The series included 9 patients with multilevel cervical stenosis. After decompression, 10 mL of water-soluble contrast agent was administered via a lumbar drainage and the operating table was tilted. Thereafter, a 3D fluoroscopy scan (O-Arm) was performed and visually evaluated. Findings. The quality of multiplanar images was sufficient to supply information about the presence of residual stenosis. After instrumentation, metal artifacts lowered image quality. In 3 cases, decompression was continued because myelography depicted residual stenosis. In one case, anterior corpectomy was not completed because myelography showed sufficient decompression after 2-level discectomy. Interpretation. Intraoperative myelography using 3D rotational fluoroscopy is useful for the control of surgical decompression in multilevel spinal stenosis providing images comparable to postmyelographic CT. The long duration of contrast delivery into the cervical spine may be solved by preoperative contrast administration. The method is susceptible to metal artifacts and, therefore, should be applied before metal implants are placed.
منابع مشابه
3D rotational fluoroscopy for intraoperative clip control in patients with intracranial aneurysms - assessment of feasibility and image quality
BACKGROUND Mobile 3D fluoroscopes have become increasingly available in neurosurgical operating rooms. In this series, the image quality and value of intraoperative 3D fluoroscopy with intravenous contrast agent for the evaluation of aneurysm occlusion and vessel patency after clip placement was assessed in patients who underwent surgery for intracranial aneurysms. MATERIALS AND METHODS Twelv...
متن کاملThree-dimensional rotational myelography.
Three-dimensional (3D) rotational radiography, initially developed to visualize intracranial aneurysms, is applied to the cervical spine after conventional myelography. We call this process 3D rotational myelography. 3D reconstruction and then postprocessing allows imaging in multiple planes. Spinal or nerve root sheath alterations caused by bony or soft tissue can be visualized and differentia...
متن کاملComparison between Iodixanol and Iohexol for Cervical Myelography in Cat
Objective- To evaluate and compare the radiographic efficacy and safety of a non-ionic dimeric and isotonic iodinated contrast medium, iodixanol (320 mgI/ml) and a non-ionic monomer and hypertonic contrast medium, iohexol (300 mgI/ml) in feline cervical myelography. Design- Experimental study Animals- Five adult healthy cats. Procedures- Iodixanol and iohexol were injected into the cerebello...
متن کاملIntraoperative Myelography in Transpsoas Lateral Lumbar Interbody Fusion for Degenerative Lumbar Spinal Stenosis: A Preliminary Prospective Study
Aim To investigate the feasibility and effectiveness of intraoperative myelography in determining adequacy of indirect spinal canal decompression during transpsoas lateral lumbar interbody fusion (LLIF). Methods Seven patients diagnosed with degenerative lumbar spinal stenosis (DLSS) were prospectively included to this study. All patients underwent LLIF and subsequently received intraoperativ...
متن کاملImproved Visualization of Intracranial Vessels with Intraoperative Coregistration of Rotational Digital Subtraction Angiography and Intraoperative 3D Ultrasound
INTRODUCTION Ultrasound can visualize and update the vessel status in real time during cerebral vascular surgery. We studied the depiction of parent vessels and aneurysms with a high-resolution 3D intraoperative ultrasound imaging system during aneurysm clipping using rotational digital subtraction angiography as a reference. METHODS We analyzed 3D intraoperative ultrasound in 39 patients wit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2015 شماره
صفحات -
تاریخ انتشار 2015