Goniometer Crosstalk Compensation for Knee Joint Applications

نویسندگان

  • Tatiana de Oliveira Sato
  • Gert-Åke Hansson
  • Helenice Jane Cote Gil Coury
چکیده

Electrogoniometers are prone to crosstalk errors related to endblocks rotation (general crosstalk) and to the characteristics of each sensor (individual crosstalk). The aim of this study was to assess the crosstalk errors due to endblock misalignments and to propose a procedure to compensate for these errors in knee applications. A precision jig was used to simulate pure ± 100° flexion/extension movements. A goniometer was mounted with various degrees of valgus/varus (± 20°) and rotation (± 30°) misalignments. For valgus/varus misalignments, although offset compensation eliminated the error in the valgus/varus recordings for 0° of flexion/extension and reduced it to a few degrees for small (± 30°) flexion/extension angles (root mean square error = 1.1°), the individual crosstalk caused pronounced errors for large (± 100°) angles (18.8°). Subsequent compensation for this crosstalk reduced these errors to 0.8° and 4.5°, respectively. For rotational misalignment, compensation for the general crosstalk by means of coordinate system rotation, in combination with compensation for the individual crosstalk, reduced the errors for small (± 30°) and large (± 100°) flexion/extension angles from 3.6° to 0.5° and from 15.5° to 2.4°, respectively. Crosstalk errors were efficiently compensated by the procedures applied, which might be useful in preprocessing of knee functional data, thereby substantially improving goniometer accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter-rater and intra-rater reliability of the fluid goniometer for measuring active knee flexion in painful knees; correlations do not mean agreement

[Purpose] The fluid goniometer is an instrument for measuring range of motion. Reliability of the fluid goniometer has not been established for subjects with painful knee joints. The purpose of this study was to determine the inter-rater and intra-rater reliability of the fluid goniometer in measuring active knee flexion of painful knees and to test its agreement with the gold standard ruler go...

متن کامل

Goniometric alignment of the normal knee joint and the factors which affect it.

OBJECTIVES Establishing a normative database for anterior plane knee joint alignment in a population is helpful in assessing patients with disorders of the knee joint specially osteoarthritis. Therefore we aimed at establishing the normal alignment in the Sri Lankan adult population using the goniometer which is an inexpensive and simple method of measurement. METHODS A total of 420 healthy a...

متن کامل

بررسی تاثیر تمرینات زنجیره حرکتی باز، بسته و تعادلی بر خطای حس عمقی مفصل زانو در زنان جوان سالم

 Background: Injuries such as osteoarthritis may impair knee joint properioception that could result in further knee joint injuries. Different exercises are attempted to recover this sense so that favorable movement and stability can be achieved in different static and dynamic situations. Prior investigator  have recommended a combination of closed chain and balance exercise for the affected in...

متن کامل

A comparative assessment of alternatives to the full-leg radiograph for determining knee joint alignment

UNLABELLED BACKGROUND The purpose of this study was to assess the concurrent validity of alternative measures of frontal plane knee alignment, namely the radiographic anatomic axis and two clinical measures in patients complaining of knee malalignment as compared with the mechanical axis on full-length radiograph of lower limbs. METHODS The knee-alignment angle was measured in 100 knees of...

متن کامل

Experimental Evaluation of a Goniometer For the Identification of Anatomical Joint Motions

This paper exposes the experimental evaluation of a new technique for the estimation of the instantaneous helical axis of movement of human anatomical joints. The measurement technique, using a six degrees of freedom spatial electro-goniometer, is tested onto a simple revolute joint and onto a subject’s knee. A motion capture system with active optical markers is used at the same time in order ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010