Transapical implantation of a self-expanding aortic valve bioprosthesis--animal feasibility study.
نویسندگان
چکیده
BACKGROUND Severe peripheral arterial disease may pose a limitation to the applicability of trans-arterial aortic valve implantation in patients who are otherwise candidates. For this reason, transapical aortic valve implantation has been proposed as a possible alternative. OBJECTIVE To evaluate the acute safety and performance of a specially designed delivery system, the CoreValve Tranzap delivery catheter, for the transapical implantation of a self-expandable aortic valve prosthesis in a porcine animal model. METHODS Thirteen pigs were implanted with a self-expandable aortic valve bioprosthesis using a 21F catheter delivery system through a transapical approach. The delivery system was evaluated for: (1) the ability to access the implantation site; (2) the ability to precisely position the delivery catheter; (3) control of the delivery of the prosthesis; (4) safe retrieval of the delivery catheter; and (5) the ability to close the apical access site of the heart. RESULTS Successful implantation was achieved in 100% of the cases. The following points were achieved in all animals: (1) passage of the delivery catheter through an incision in the left ventricular apex; (2) positioning of the delivery catheter on the implantation site; (3) controlled deployment of the aortic valve prosthesis; (4) the safe retrieval of the delivery catheter system; and (5) the adequate closure of the apex of the heart. CONCLUSION This study demonstrates the acute safety and feasibility of the CoreValve Tranzap delivery system for the transapical implantation of the CoreValve self-expanding aortic valve bioprosthesis in a porcine animal model.
منابع مشابه
Transapical aortic valve implantation with a self-expanding anatomically oriented valve.
AIMS The Medtronic Engager™ aortic valve bioprosthesis is a self-expanding valve with support arms facilitating anatomically correct positioning and axial fixation. Valve leaflets, made of bovine pericardium, are mounted on a Nitinol frame. Here, we report the first in man study with this new implant (Trial Identifier NCT00677638). METHODS AND RESULTS Thirty patients (mean age 83.4 ± 3.8 year...
متن کاملPreliminary feasibility and hemodynamic performance of a newly-developed self-expanding bioprosthesis and 16-F delivery system in transcatheter aortic valve implantation in sheep
We sought to evaluate the feasibility and hemodynamic performance of a new self-expanding bioprosthesis and 16-F delivery system in sheep. A 23-mm new self-expanding aortic bioprosthesis was implanted in sheep (n = 10) with a 16-F catheter via the right common carotid artery. Each sheep underwent angiography and coronary angiography before intervention, immediately and 1 h after stent implantat...
متن کاملThe Self-Expanding Symetis Acurate Does Not Increase Cerebral Microembolic Load When Compared to the Balloon-Expandable Edwards Sapien Prosthesis: A Transcranial Doppler Study in Patients Undergoing Transapical Aortic Valve Implantation
OBJECTIVES The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system. BACKGROUND Recently, the Symetis Acurate TA revalving system has been introduce...
متن کاملEmergency transapical mitral valve-in-valve implantation for bioprosthesis failure: transapical implantation of an Edwards Sapien-XT in a dysfunctional mitral bioprosthesis in a critical patient
Background: Valve-in-Valve (VIV) Transcatheter Aortic Valve Replacement (TAVR) is now the treatment of choice in high-surgical-risk patients with failing aortic bioprosthesis. Although less performed, VIV-Transcatheter Mitral Valve Replacement (TMVR) is a valid treatment option for selected high-risk patients with degenerated mitral bioprostheses. Several cases of elective ViVTAVR and -TMVR hav...
متن کاملTransapical aortic valve implantation: results of a Brazilian prosthesis.
OBJECTIVE The aortic valve replacement is a routine procedure with acceptable risk, but in some cases, such a risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation has been viable, with lower morbidity and mortality. The aim of this study was to develop a national catheter-mounted aortic bioprosthesis for the aortic position implant. METHODS After a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 36 5 شماره
صفحات -
تاریخ انتشار 2009