Reduced Leaflet Stress in the Stentless Quadrileaflet Mitral Valve: A Finite Element Model
نویسندگان
چکیده
BACKGROUND Failure of bioprosthetics is usually caused by calcification of the leaflets as a consequence of high tensile stresses. The stentless valve resembles native mitral valve anatomy, has a flexible leaflet attachment and a suspension at the papillary muscles, and preserves annuloventricular continuity. In this study, the effects of the stentless valve design on leaflet stress were investigated with a finite element model. METHODS Finite element models of the stentless quadrileaflet mitral valve were created in the close and open configurations. The geometry of the stented trileaflet mitral valve was also analyzed for comparative purposes. Under the designated pressures, the regional stresses were evaluated, and the distributions of stresses were assessed. RESULTS Regardless of whether the valve is in the open or close configuration, the maximum first principal stress was significantly lower in the stentless valve than in the stented valve. For the stentless valves, limited stress concentration was discretely distributed in the papillary flaps under both close and open conditions. In contrast, in the stented valve, increased stress concentration was evident at the central belly under the open condition and at the commissural attachment under close condition. In either configuration, the maximum second principal stress was markedly lower in the stentless valve than in the stented valve. CONCLUSIONS The stentless valve was associated with a significant reduction in leaflet stress and a more homogeneous stress distribution compared to the stented valve. These findings are consistent with recent reports of the clinical effectiveness of the stentless quadrileaflet mitral valve.
منابع مشابه
Patient-specific simulation of a stentless aortic valve implant: the impact of fibres on leaflet performance.
In some cases of aortic valve leaflet disease, the implant of a stentless biological prosthesis represents an excellent option for aortic valve replacement (AVR). In particular, if compared with the implant of mechanical valves, it provides a more physiological haemodynamic performance and a reduced thrombogeneticity, avoiding the use of anticoagulants. The clinical outcomes of AVR are strongly...
متن کاملA finite shell element for heart mitral valve leaflet mechanics, with large deformations and 3D constitutive material model.
This paper presents a shell finite element formulation appropriate for simulating the heart valve leaflet mechanics, including three-dimensional (3D) stress and strain effects. A 4-node mixed-interpolation shell is formulated in convected coordinates. This shell model is made capable of handling arbitrary 3D material models by use of an algorithm that satisfies the shell stress assumption at ev...
متن کاملA large-strain finite element formulation for biological tissues with application to mitral valve leaflet tissue mechanics.
This paper presents a finite element formulation suitable for large-strain modeling of biological tissues and uses this formulation to implement an accurate finite element model for mitral valve leaflet tissue. First, an experimentally derived strain energy function is obtained from literature. This function is implemented in finite elements using the mixed pressure-displacement formulation. A ...
متن کاملبررسی عوامل موثر در افزایش سطح دریچه و پیدایش نارسایی میترال بعد از بالون میترال والولوپلاستی در 110 بیمار در مجتمع بیمارستانی امام خمینی
Background: Percutaneous Transeptal Mitral Commisurotomy (PTMC) has been used in treating mitral stenosis with variable success, its main complication being mitral incompetence. There is a need to define the subgroup of the patients who benefit mostly from the procedure. Methods: We studied 110 patients (age 17 to 60 years mean 33.2) with mitral stenosis. PTMC was performed though femoral vein....
متن کاملFlat or curved pericardial aortic valve cusps: a finite element study.
BACKGROUND AND AIM OF THE STUDY The finite element method (FEM) has frequently been used to investigate the behavior of the aortic valve, but studies on the performance and behavior of free-hand autologous pericardial aortic valves reconstructed using specially designed valve molds have not been performed. The study aim was to demonstrate the effectiveness of a three-dimensional (3-D) cusp of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2013