Misuse and interlaboratory test reproducibility of API 20E system.
نویسندگان
چکیده
One hundred strains were referred to us for identification because they apparently could not be identified satisfactorily with the API 20E system (appareils et procédés d'identification). The inability to identify 31 strains was due primarily to failure to follow the manufacturer's instructions. Twenty six further strains were found to have been correctly identified by the sender's own API 20E results, so that only the remaining 43 strains definitely fell into the category for which our identification service was intended. Eighteen of the 43 strains not identified by the sender were identified by us using the API 20E system, and several possible reasons are given to explain the differences in these results. The remaining 25 strains either could not be identified by us on the API 20E system or, in the case of 13, they could not be identified by our conventional system and therefore no comparison could be made. The average interlaboratory probability of errors for the API 20E tests was 6.1%.
منابع مشابه
Reproducibility of the analytab (API 20E) system.
The reproducibility of the Analytab (API 20E) system for identification of Enterobacteriaceae was evaluated with 110 clinical isolates. Each isolate was identified by two technologists at different times. Genus-species identification was 97.3% reproducible; however, only 55.5% of the strains gave identical reactions in all 20 of the API 20E biochemical tests on repeat testing. Of those strains ...
متن کاملComparative study of three methods of identification of Enterobacteriaceae.
Three separate hospital clinical microbiology laboratories using three different identification systems participated in the identification of Enterobactericeae from a central pool of 'unknown" clinical isolates. With conventional tubed media, API-20E (Anlytab Products Inc.) and R/B tube (Corning Diagnostics) systems, there was a 91.1% agreement in the species designation. No significant differe...
متن کاملThe comparison of PCR technique and API-20E kit with the conventional biomedical methods for the identification of Salmonella species in laboratory
Abstract Bachground and objectives: Salmonella is one of the most important agents of gastrointestinal infection and diarrhea in our country. Misdiagnosis of these bacteria leads to cure failure. The aim of this study was to make a comparison between PCR and the API-20E and conventional biochemical tests carried out for the identification of Salmonella. Material and Methods: In this study 470 s...
متن کاملMulticenter evaluation of the MicroScan Rapid Gram-Negative Identification Type 3 Panel.
The accuracy and performance of the revised MicroScan Rapid Gram-Negative Identification Type 3 Panel (Dade MicroScan Inc., West Sacramento, Calif.) were examined in a multicenter evaluation. The revised panel database includes data for 119 taxa covering a total of 150 species, with data for 12 new species added. Testing was performed in three phases: the efficacy, challenge, and reproducibilit...
متن کاملIdentification of Yersinia spp. with the API 20E system.
The ability of the API 20E system to identify 105 clinical isolates of Yersinia spp. was compared with those of conventional biochemical tests at 28 and 37 degrees C. Elimination of the Voges-Proskauer test (recorded as a negative result) increased the percentage of correct identifications for Yersinia spp. from 66 to 93% when the API 20E strips were incubated at 28 degrees C.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 38 8 شماره
صفحات -
تاریخ انتشار 1985