High survivorship with a titanium-encased alumina ceramic bearing for total hip arthroplasty.
نویسندگان
چکیده
BACKGROUND Although ceramic-on-ceramic bearings for total hip arthroplasty (THA) show promising results in terms of bearing-surface wear, fracture of the bearing, insertional chips, and squeaking remain a concern. QUESTIONS/PURPOSES Our primary objective of this report was to determine overall survivorship of a titanium-encased ceramic-on-ceramic bearing couple. Our secondary objectives were to evaluate for ceramic fracture, insertional chips, osteolysis, and device squeaking. METHODS Six surgeons at six institutions implanted 194 patients (209 hips) with an average age of 52 years with cementless hips and alumina ceramic bearings. One hundred thirty-seven patients (146 hips) have 10-year followup (70%). We determined Kaplan-Meier survivorship of the bearing surface and implant system and collected radiographic and clinical data to evaluate for osteolysis and squeaking. RESULTS Survivorship using revision for any reason as the end point was 97% at 10 years and survivorship end point bearing surface failure or aseptic loosening of 99%. There was one ceramic insert fracture (0.5%), there were no insertional chips, there was no visible osteolysis on AP and lateral radiographs, and there was a 1% patient-self-reported incidence of squeaking at the last clinical followup. Six hips underwent revision (3.7%). CONCLUSIONS Ceramic bearings for THA with a titanium-encased insert have high survivorship at 10 years followup and a fracture risk of 0.5%. We found at last followup on routine radiographs no evidence of osteolysis, and no patient has been revised for squeaking or has reported dissatisfaction with the clinical result because of noise. IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
منابع مشابه
Two- to 9-year clinical results of alumina ceramic-on-ceramic THA.
From June 1997 to June 2003 we performed 194 total hip arthroplasties on 173 patients using alumina ceramic-on-ceramic bearings as part of a prospective United States Food and Drug Administration/Investigational Device Exemption study. The average patient age at surgery was 49.9 years. Minimum followup time was 2 years (mean 4.3 years, range 2-9 years). We evaluated survival rate, implant- and ...
متن کاملCeramic failure after total hip arthroplasty with an alumina-on-alumina bearing.
BACKGROUND The mechanical properties of alumina ceramic, now in its third generation, have been markedly improved through the evolution of design features and manufacturing processes and the introduction of proof-testing. Nonetheless, because of the lack of ductility of alumina ceramic, there is concern regarding the risk of fracture during insertion or in vivo use. The purpose of the present s...
متن کاملA comparison of polyethylene wear between cobalt-chrome ball heads and alumina ball heads after total hip arthroplasty: a 10-year follow-up
STUDY DESIGN This is a retrospective study comparing polyethylene wear between ceramic ball heads and metal ball heads in total hip arthroplasty. BACKGROUND The ceramic-on-polyethylene bearing option has been introduced as an alternative to metal-on-polyethylene to minimize polyethylene wear debris and reduce subsequent osteolysis and aseptic loosening. However, the reported data were debatab...
متن کاملFatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...
متن کاملAlumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty
The long-term durability of polyethylene lining total hip arthroplasty (THA) mainly depends on periprosthetic osteolysis due to wear particles, especially in young active patients. In hip simulator study, reports revealed significant wear reduction of the alumina ceramic-on-polyethylene articulation of THA compared with metal-on-polyethylene bearing surfaces. However, medium to long-term clinic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical orthopaedics and related research
دوره 472 2 شماره
صفحات -
تاریخ انتشار 2014