Rapid pre-tension loss in the Ilizarov external fixator: an in vitro study.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Wire pre-tension in the Ilizarov frame is considered to be important in order to reduce movements that can impair fracture healing. Wires will eventually lose part of their pre-tension, however. In order to gain more insight into the need for wire pre-tension, we investigated: (1) the amount of pre-ten-sion loss, (2) the relationship between pre-tension loss and bolt-tightening torque, (3) the cause of a possible loss of pre-tension, and (4) the effect of pre-tension on cyclic micromotions and total displacement of the bone segments. METHODS 3 Ilizarov configurations, with various wire pre-tensions and bolt-tightening torques, were tested 3 times with an MTS machine. For each wire, slippage and tensions were measured for the duration of the whole experiment. RESULTS A loss of wire pre-tension (up to 75%) due to slippage was found. Higher bolt-tightening torques significantly reduced the amount of pre-tension loss. Furthermore, a higher wire pre-tension reduced the maximal axial displacement of the bone fragment. There was, however, least cyclic axial micromotion when no wire pre-tension was present -- probably due to the lack of wire recoil. INTERPRETATION Wires in an experimental Ilizarov external fixator lose pre-tension within a limited period of time, and probably also in the clinical setting. This does not seem to lead to increased cyclic axial micromotions of the bone fragements. However, the question remains as to how excessive axial displacement of the bone fragment and other loading configurations will affect the process of fracture healing in a patient.
منابع مشابه
A biomechanical analysis of the Ilizarov external fixator.
Five configurations of the Ilizarov fixator were analyzed in vitro. The overall stiffness, shear stiffness, and axial motion of the fracture site were determined. The data were compared with the results of eight conventional one-half frame fixators previously tested in the same manner. The Ilizarov fixator allowed significantly more axial motion at the fracture site during axial compression tha...
متن کاملIlizarov Versus AO External Fixator for the Treatment of Tibia Open Fractures
BACKGROUND In developing countries, Ilizarov or AO external fixator is usually used for treatment of tibial open fractures. The purpose of this study was to compare the efficacy of these two methods for treatment of tibial open fractures. METHODS From April 2002 to April 2010, 120 patients with open tibial fractures admitted to the Department of Orthopedics of Babol University of Medical Scie...
متن کاملMechanical rigidity of the Ortho-SUV frame compared to the Ilizarov frame in the correction of femoral deformity
The Ortho-SUV frame (OSF) is a novel hexapod circular external fixator which draws upon the innovation of the Ilizarov method and the advantages of hexapod construction in the three-dimensional control of bone segments. Stability of fixation is critical to the success or failure of an external circular fixator for fracture or osteotomy healing. In vitro biomechanical modelling study was perform...
متن کاملTreatment of congenital leg length discrepancies in children using an Ilizarov external fixator: a comparative study.
The purpose of this study was to evaluate the influence of intramedullary (IM) alignment used in combination with an Ilizarov external fixation on the healing index (HI) and lengthening index (LI) in the treatment of congenital leg length discrepancies (LLD). This study included 35patients aged from 3.5 to 19 (average age 10.73) who underwent thl egalisation procedure using an Ilizarov external...
متن کاملThe treatment of high tibial osteotomy non-union with the Ilizarov external fixator
To evaluate the results of the Ilizarov external fixator in the treatment of non-union post-high tibial osteotomy (HTO). Five non-unions, in four patients, following HTO were treated by Ilizarov fixation. Clinical outcome was assessed pre- and post-operatively by the Knee Society Clinical Rating System (KSCRS). Radiological analysis assessed bone healing pre- and post-operatively and measured p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica
دوره 78 5 شماره
صفحات -
تاریخ انتشار 2007