Short-Term Results of Transforaminal Lumbar Interbody Fusion Using Pedicle Screw with Cortical Bone Trajectory Compared with Conventional Trajectory

نویسندگان

  • Yuji Kasukawa
  • Naohisa Miyakoshi
  • Michio Hongo
  • Yoshinori Ishikawa
  • Daisuke Kudo
  • Yoichi Shimada
چکیده

STUDY DESIGN Case-control study. PURPOSE To evaluate clinical and radiological results of transforaminal lumbar interbody fusion (TLIF) performed with cortical bone trajectory (CBT) pedicle screw insertion with those of TLIF using 'conventional' or percutaneous pedicle screw insertion. OVERVIEW OF LITERATURE CBT is a new trajectory for pedicle screw insertion in the lumbar spine; clinical and radiological results of TLIF using pedicle screws inserted with CBT are unclear. METHODS In total, 26 patients (11 males, 15 females) were enrolled in this retrospective study and divided into three groups: TLIF with pedicle screw insertion by conventional minimally invasive methods via the Wiltse approach (M-TLIF, n=10), TLIF with percutaneous pedicle screw insertion (P-TLIF, n=6), and TLIF with pedicle screw insertion with CBT (CBT-TLIF, n=10). Surgical results and preand postoperative radiological findings were evaluated and compared. RESULTS Intraoperative blood loss was significantly less with CBT-TLIF (p=0.03) than with M-TLIF. Postoperative lordotic angles did not differ significantly among the three groups. Complete fusions were obtained in 10 of 12 levels (83%) with M-TLIF, in seven levels (100%) with P-TLIF, and in 10 of 11 levels (91%) with CBT-TLIF. On postoperative computed tomography, correct positioning was seen in 84.1% of M-TLIF screws, 88.5% of P-TLIF screws, and 90% of CBT-TLIF screws. CONCLUSIONS CBT-TLIF resulted in less blood loss and a shorter operative duration than M-TLIF or P-TLIF. Postoperative rates of bone union, maintenance of lordotic angles, and accuracy of pedicle screw positions were similar among the three groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Midline Lumbar Fusion with Cortical Bone Trajectory Screw

A novel cortical bone trajectory (CBT) screw technique provides an alternative fixation technique for lumbar spine. Trajectory of CBT screw creates a caudo-cephalad path in sagittal plane and a medio-lateral path in axial plane, and engages cortical bone in the pedicle. The theoretical advantage is that it provides enhanced screw grip and interface strength. Midline lumbar fusion (MIDLF) is com...

متن کامل

Transforaminal lumbar interbody fusion with cortical bone trajectory screws versus traditional pedicle screws fixation: a study protocol of randomised controlled trial

INTRODUCTION Transforaminal lumbar interbody fusion (TLIF) has been widely used in the treatment of lumbar degenerative disc disorders and shows favourable clinical results. Recently, cortical bone trajectory (CBT) has become a new trajectory for screw insertion in the lumbar spine. Several biomechanical studies have demonstrated that the CBT technique achieves screw purchase and strength great...

متن کامل

A prospective, cohort study comparing translaminar screw fixation with transforaminal lumbar interbody fusion and pedicle screw fixation for fusion of the degenerative lumbar spine.

In a prospective observational study we compared the two-year outcome of lumbar fusion by a simple technique using translaminar screws (n = 57) with a more extensive method using transforaminal lumbar interbody fusion and pedicular screw fixation (n = 63) in consecutive patients with degenerative disease of the lumbar spine. Outcome was assessed using the validated multidimensional Core Outcome...

متن کامل

Fixation Strength of Caudal Pedicle Screws after Posterior Lumbar Interbody Fusion with the Modified Cortical Bone Trajectory Screw Method

STUDY DESIGN Clinical case series. PURPOSE In the posterior lumbar interbody fusion (PLIF) procedure in our institute, the cephalad screw trajectory follows a mediolateral and caudocephalad directed path according to the original cortical bone trajectory (CBT) method. However, the starting point of the caudal screw is at the medial border of the pedicle on an articular surface of the superior...

متن کامل

Endoscopic transforaminal decompression, interbody fusion, and percutaneous pedicle screw implantation of the lumbar spine: A case series report

BACKGROUND On the basis of the experiences gained from conventional open spinal procedures, a long list of desirable objectives have emerged with the evolution of the lesser invasive spinal procedures. At the top of that list is the desire to minimize the trauma of surgery. The rest of the objectives, which include reductions of operating time, surgical blood loss, hospital stay, postoperative ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015