Stability-indicating high-performance thin-layer chromatographic method for analysis of itraconazole in bulk drug and in pharmaceutical dosage form

نویسندگان

  • Shalin K. Parikh
  • Jayant B. Dave
  • Chhagan N. Patel
  • Badmanaban Ramalingan
چکیده

BACKGROUND A new, simple, selective, precise, and stability-indicating high-performance thin-layer chromatographic method has been established for analysis of itraconazole (ITZ) in the bulk drug and in pharmaceutical formulations. Separation was achieved on aluminium plate precoated with silica gel 60F254 using Toluene : Chloroform : Methanol [5: 5: 1.5(v/v)] as mobile phase. Densitometric analysis was performed at 260 nm. RESULT Compact bands of ITZ were obtained at Rf 0.52 ± 0.02. Linearity (R(2) = 0.9978), limit of detection (180.29 ng/band), limit of quantification (546.34 ng/band), recovery (98-102%), and precision (≤0.51%) were satisfactory. Drug was not degraded under neutral and alkaline hydrolysis, UV and photolytic degradation, under-elevated temperature, and humidity. ITZ is degraded under acidic hydrolysis and oxidative condition; the degraded products were well resolved from individual bulk drug response. Developed method can effectively resolve drug from its excipients in capsule dosage form. The specificity of the method was confirmed by peak purity of resolved peak. CONCLUSION The method can be applicable for routine analysis of ITZ in pharmaceutical formulation as stability-indicating. Because the method can effectively separate the drug from its degradation products as well as excipients, it can be used as a stability-indicating method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form

A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...

متن کامل

A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form

A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...

متن کامل

Development and Validation of a Stability-Indicating High Performance Thin Layer Chromatography (HPTLC) Method for estimation of Canagliflozin in bulk and Pharmaceutical Dosage Form

Article history: Received on: 30/01/2016 Revised on: 13/03/2016 Accepted on: 06/04/2016 Available online: 28/05/2016 The objective of the study was to develop and validate simple, authentic and stability indicating high performance thin-layer chromatographic method for determination of Canagliflozin in bulk and pharmaceutical formulations as per ICHQ2 R1 Guidelines. HPTLC aluminium plates Preco...

متن کامل

Stress Studies of Tenofovir Disoproxil Fumarate by HPTLC in Bulk Drug and Pharmaceutical Formulation

A stability-indicating high-performance thin-layer chromatographic (HPTLC) method for determination of tenofovir disoproxil fumarate in bulk drug and in tablet has been developed and validated. The mobile phase selected was chloroform:methanol (9.0:1.0, v/v) with ultraviolet (UV) detection at 260 nm. The retention factor was found to be 0.49 ± 0.03 with correlation coefficients of 0.9994 in the...

متن کامل

A Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms

Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2011