F eb 2 00 4 Measurements of Compton Scattered Transition Radiation at High Lorentz Factors

نویسندگان

  • Michael L. Cherry
  • Joachim Isbert
  • Donald Patterson
  • John W. Mitchell
چکیده

X-ray transition radiation can be used to measure the Lorentz factor of relativistic particles. Standard transition radiation detectors (TRDs) typically incorporate thin plastic foil, foam, or fiber radiators and gas-filled x-ray detectors, and are sensitive up to γ ∼ 10. To reach Lorentz factors up to γ ∼ 10, thicker, denser radiators can be used, which consequently produce x-rays of harder energies (& 100 keV). At these energies, scintillator detectors are more efficient in detecting the hard x-rays, and Compton scattering of the x-rays out of the path of the particle becomes important. The Compton scattering can be utilized to separate the transition radiation from the ionization background spatially. The use of conducting metal foils is predicted to yield enhanced signals compared to standard nonconducting plastic foils of the same dimensions. We have designed and built an inorganic scintillator-based Compton Scatter TRD optimized for high Lorentz factors and exposed it to high energy electrons at the CERN SPS. We present the results of the accelerator tests and comparisons to simulations, demonstrating 1) the effectiveness of the Compton Scatter TRD approach; 2) the performance of conducting aluminum foils; and 3) the ability of a TRD to measure energies approximately an order of magnitude higher than previously used in very high energy cosmic ray studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ar X iv : a st ro - p h / 04 08 21 5 v 1 1 2 A ug 2 00 4 Unidentified γ - ray sources off the Galactic plane as low - mass microquasars ?

A subset of the unidentified EGRET γ-ray sources with no active galactic nucleus or other conspicuous counterpart appears to be concentrated at medium latitudes. Their long-term variability and their spatial distribution indicate that they are distinct from the more persistent sources associated with the nearby Gould Belt. They exhibit a large scale height of 1.3±0.6 kpc above the Galactic plan...

متن کامل

Simulation Studies of Delta-ray Backgrounds in a Compton-Scatter Transition Radiation Detector

In order to evaluate the response to cosmic-ray nuclei of a Compton-Scatter Transition Radiation Detector in the proposed ACCESS space-based mission, a hybrid Monte Carlo simulation using GEANT3 and an external transition radiation (TR) generator routine was constructed. This simulation was employed to study the effects of delta-ray production induced by high-energy nuclei and to maximize the r...

متن کامل

ar X iv : h ep - p h / 04 12 02 3 v 1 2 D ec 2 00 4 Radiation in Lorentz violating electrodynamics

Synchrotron radiation is analyzed in the classical effective Lorentz invariance violating model of Myers-Pospelov. Within the full far-field approximation we compute the electric and magnetic fields, the angular distribution of the power spectrum and the total emitted power in the m-th harmonic, as well as the polarization. We find the appearance of rather unexpected and large amplifying factor...

متن کامل

Multiwavelength study of Cygnus A II. X-ray inverse-Compton emission from a relic counterjet and implications for jet duty-cycles

The duty-cycle of powerful radio galaxies and quasars such as the prototype Cygnus A is poorly understood. X-ray observations of inverse-Compton scattered Cosmic Microwave Background (ICCMB) photons probe lower Lorentz-factor particles than radio observations of synchrotron emission and thus potentially reveal a more aged population. Comparative studies of the nearer and further lobes, separate...

متن کامل

9 F eb 2 00 9 Improvements to the ILC Upstream Polarimeter

Since the ILC is designed to allow measurements of masses and cross-sections of Standard Model as well as of possible new particles at the permille level, also the beam parameters like beam energy, polarisation and luminosity have to be controlled to this precision. While for the beam energy this goal has already been achieved at previous colliders, the up to now most precise polarisation measu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004