Effects of a new evaporative cooling solution during rowing in a warm environment.

نویسندگان

  • Inigo Mujika
  • Rafa González De Txabarri
  • David Pyne
چکیده

UNLABELLED Energicer is a new solution which purportedly increases evaporative cooling during exercise in the heat. PURPOSE To evaluate the effect of Energicer on performance during indoor rowing in a warm environment. METHODS Eighteen highly trained rowers (age 23.3 ± 6.7 y, height 181.3 ± 6.0 cm, mass 76.7 ± 5.0 kg, peak aerobic power (PAP) 322.1 ± 24.3 W; mean ± SD) performed two indoor rowing trials at 25.0 degrees Celsius and 65.0% relative humidity. Each trial consisted of 10 min at 55% PAP, 5 min of rest, 10 min at 70% PAP, 10 min of rest, and 2000 m time trial. Subjects were randomly assigned to an experimental (COOL) or a placebo (PLA) condition, using a double-blind, crossover design. During COOL, subjects wore sweatbands soaked in Energicer on both forearms; during PLA, they wore identical sweatbands soaked in cool water. Physiological measures and rowing performance were analyzed in a post-test-only crossover design. Magnitude of the difference between treatments was interpreted using the Cohen's effect statistic. RESULTS No substantial differences were observed in heart rate, blood lactate and RPE between treatments during the submaximal row (COOL 163 ± 10 bpm, 4.3 ± 1.0 mM, 14.5 ± 1.8; PLA 165 ± 11 bpm, 4.8 ± 1.4 mM, 14.6 ± 1.6) and the time trial (COOL 179 ± 9 bpm, 10.7 ± 2.3 mM, 20 ± 0; PLA 179 ± 10 bpm, 11.1 ± 2.2 mM, 20 ± 0). Time (419 ± 11 vs 420 ± 12 s), mean power (305 ± 24 vs 304 ± 26 W), sweat loss (1013 ± 186 vs 981 ± 161 mL) and pacing strategy during the time trial were similar in COOL and PLA. The magnitude of differences between treatments was trivial for all measured variables. CONCLUSION Energicer failed to provide a substantial benefit during indoor rowing in a warm environment. Whether Energicer is beneficial during more prolonged exercise and/or under more stressful environmental conditions remains to be elucidated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization and increase production and efficiency of gas turbines GE-F9 using Media evaporative cooler in Fars combined cycle power plant

Gas turbines play an important role in supplying power for the country especially in peak electricity load. The main disadvantages are the turbines, they produce large changes are a result of climate change. However, in times of peak electricity grid and at the same time warm months, can produce gas turbines under the effect of ambient temperature, the amount of reduced considerably. The method...

متن کامل

Evaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners

There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...

متن کامل

Design and construction of evaporative local cooling coatings and evaluate their efficiency in improving some perceptual indicators in laboratory conditions

Introduction: One way to reduce the level of heat strain is to use personal evaporative cooling coats. such as the wrist, ankle, head and neck. The purpose of this study is to design, construct, and determine the cooling power of local cooling coatings and evaluate their efficiency in improving perceptual indicators in the laboratory. Materials and Methods: Initially, the design and constructio...

متن کامل

Evaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners

There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...

متن کامل

Effect of Using Evaporative Condenser Instead of Air Condenser in Window-air Conditioners

In this paper,&#10 the application of evaporative cooling for refrigeration cycle to reduce power consumption in hot climates is emphasized. Experimental and analytical investigations were performed in order to specify the effect of evaporative cooling condenser instead of the commonly used air cooling condenser in window-air-conditioners. Evaporative condenser can reject more heat, thereby pre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • International journal of sports physiology and performance

دوره 5 3  شماره 

صفحات  -

تاریخ انتشار 2010