Ascending aortic approach for balloon aortic valvuloplasty with concomitant bilateral pulmonary artery banding in a very low-birth-weight neonate with critical aortic stenosis and poor left ventricular function.

نویسندگان

  • Mitsutoshi Kimura
  • Yasushi Misaki
  • Hitoshi Kato
  • Yukihiro Kaneko
چکیده

An 1186-g infant was born at 27 weeks' gestation. Echocardiography showed critical aortic stenosis, a dilated left ventricle (left ventricular end-diastolic diameter, 16.9 mm), and poor left ventricular function (left ventricular ejection fraction, 8.5%). Due to duct-dependent systemic circulation, the patient underwent a hybrid intervention consisting of bilateral pulmonary artery banding (PAB) and balloon aortic valvuloplasty (BAV) via the ascending aorta on day 2. A stainless steel tip and a 6-French introducer were combined to create an access device. The access device was inserted into the ascending aorta, through which balloon catheters were manipulated. On day 4, echocardiography showed a left ventricular ejection fraction of 48% and dominant antegrade blood flow in the aortic arch. The pulmonary artery bands were removed and the ductus was clipped on day 8 to establish in-line circulation. After re-balloon aortic valvuloplasty for restenosis, the patient was discharged from the hospital at 7 months of age. The clinical implications of this case are: the ascending aortic approach is feasible for BAV in low-birth-weight neonates; and bilateral PAB performed concomitantly with BAV may be efficient for neonates with critical aortic stenosis and poor left ventricular function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی نتایج پیگیری یک ساله بالون والولوپلاستی تنگی مادرزادی دریچه آئورت در کودکان به مدت 10 سال در بیمارستان قلب شهید رجایی

Abstract Background: Balloon valvuloplasty uses for treatment of aortic stenosis from 20 years ago. Regarding loss of information about results of balloon valvuloplasty of hereditary aortic stenosis, this study was done to determine prognosis and complication of balloon valvuloplasty during last 10 years. Methods: This study was done on existing data of all children with hereditary aortic...

متن کامل

Antegrade balloon valvuloplasty for critical aortic stenosis in a premature neonate weighing 1100 g.

Experiences with invasive cardiac catheterization in low birth weight infants are few. In our clinic, we performed balloon aortic valvuloplasty by antegrade approach in a neonate weighing 1100 g with critical aortic stenosis, patent ductus arteriosus and atrial septal defect. The right femoral vein was accessed with a 4 Fr sheath, and a catheter was placed into the left ventricle from the atria...

متن کامل

مقایسه نتایج درمانی بالون والوپلاستی و والوتومی جراحی در بیماران مبتلا به تنگی مادرزادی دریچه آئورت در پیگیری 6 ساله در بخش کودکان بیمارستان قلب شهید رجایی تهران

Background: Balloon valvuloplasty is a relatively new technique for relief of obstruction of aortic valve. The primary results of this procedure are similar to surgical valvotomy with fewer complications and mortality. Materials and methods: One hundred fifty-five patients with congenital aortic stenosis were enrolled in this study over a period of 6 years (1991-1997). Participants were all un...

متن کامل

Restrictive perimembranous ventricular septal defect with left to right Shunt post urgent aortic balloon valvuloplasty and transcatheter aortic valve replacement

An 86-year-old male patient was admitted in our cardiology ward with signs of congestive biventricular heart failure. The patient presented with deteriorating dyspnea on mild exertion and at rest the last days, compatible with class NYHA III-IV heart failure, bilateral peripheral oedema, increased NT-proBNP (9198 pg/mL), mildly elevated Troponin (TnT 64 pg/mL), interstitial pulmonary oedema and...

متن کامل

[Severe aortic stenosis and cardiogenic shock: a therapeutic challenge].

Acute heart failure in patients with severe aortic stenosis and left ventricular systolic dysfunction is well known for its dire prognosis and limited therapeutic options. The authors describe the case of a man admitted for non-ST-elevation myocardial infarction. Diagnostic exams revealed severe aortic stenosis, with good left ventricular systolic function, and two-vessel coronary artery diseas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 41 1  شماره 

صفحات  -

تاریخ انتشار 2012