TRIGEN INTERTAN intramedullary nail versus sliding hip screw: a prospective, randomized multicenter study on pain, function, and complications in 684 patients with an intertrochanteric or subtrochanteric fracture and one year of follow-up.
نویسندگان
چکیده
BACKGROUND Both intramedullary nails and sliding hip screws are used with good results in the treatment of intertrochanteric and subtrochanteric fractures. The aim of our study was to assess whether use of the TRIGEN INTERTAN nail, as compared with a sliding hip screw, resulted in less postoperative pain, improved functional mobility, and reduced surgical complication rates for patients with an intertrochanteric or subtrochanteric fracture. METHODS In a prospective, randomized multicenter study, 684 elderly patients were treated with the INTERTAN nail or with a sliding hip screw with or without a trochanteric stabilizing plate. The patients were assessed during their hospital stay and at three and twelve months postoperatively. A visual analogue scale (VAS) pain score was recorded at all time points, and functional mobility was assessed with use of the timed Up & Go test. The Harris hip score (HHS) was used to assess hip function more specifically. Quality of life was measured with the EuroQol-5D (EQ-5D). Radiographic findings as well as intraoperative and postoperative complications were recorded and analyzed. RESULTS Patients treated with an INTERTAN nail had slightly less pain at the time of early postoperative mobilization (VAS score, 48 versus 52; p = 0.042), although this did not influence the length of the hospital stay and there was no difference at three or twelve months. Regardless of the fracture and implant type, functional mobility, hip function, patient satisfaction, and quality-of-life assessments were comparable between the groups at three and twelve months. The numbers of patients with surgical complications were similar for the two groups (twenty-nine in the sliding-hip-screw group and thirty-two in the INTERTAN group, p = 0.67). CONCLUSIONS INTERTAN nails and sliding hip screws are similar in terms of pain, function, and reoperation rates twelve months after treatment of intertrochanteric and subtrochanteric fractures.
منابع مشابه
TRIGEN INTERTAN Intramedullary Nail Versus Sliding Hip Screw
Background: Both intramedullary nails and sliding hip screws are used with good results in the treatment of intertrochanteric and subtrochanteric fractures. The aim of our study was to assess whether use of the TRIGEN INTERTAN nail, as compared with a sliding hip screw, resulted in less postoperative pain, improved functional mobility, and reduced surgical complication rates for patients with a...
متن کاملComparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures – postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate
BACKGROUND In treatment of unstable trochanteric fractures dynamic hip screw and Medoff sliding plate devices are designed to allow secondary fracture impaction, whereas intramedullary nails aim to maintain fracture alignment. Different treatment protocols are used by two similar Swedish regional emergency care hospitals. Dynamic hip screw is used for fractures considered as stable within the r...
متن کاملIs a sliding hip screw or im nail the preferred implant for intertrochanteric fracture fixation?
UNLABELLED This study was performed to determine whether patients who sustain an intertrochanteric fracture have better outcomes when stabilized using a sliding hip screw or an intramedullary nail. A 20% sample of Part A and B entitled Medicare beneficiaries 65 years or older was used to generate a cohort of patients who sustained intertrochanteric femur fractures between 1999 and 2001. Two fra...
متن کاملTwo-way compression along the shaft and the neck of the femur with the Medoff sliding plate: one-year follow-up of 108 intertrochanteric fractures.
The Medoff sliding plate (MSP) is a new device used to treat intertrochanteric and subtrochanteric fractures. There are three options for sliding; either along the shaft or the neck of the femur, or a combination of both. In a prospective series of 108 consecutive displaced intertrochanteric fractures we used combined dynamic compression. The patients were followed clinically and radiologically...
متن کاملComparison of a twin interlocking derotation and compression screw cephalomedullary nail (InterTAN) with a single screw derotation cephalomedullary nail (proximal femoral nail antirotation): a systematic review and meta-analysis for intertrochanteric fractures
BACKGROUND Intertrochanteric hip fractures are common and devastating injuries especially for the elderly. Surgical treatment is the optimal strategy for managing intertrochanteric fractures as it allows early rehabilitation and functional recovery. The relative effects of internal fixation strategies for intertrochanteric fracture after operation remain limited to relatively small studies whic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. American volume
دوره 95 3 شماره
صفحات -
تاریخ انتشار 2013