A comparison between Humphrey and frequency doubling perimetry for chiasmal visual field defects.
نویسندگان
چکیده
PURPOSE To evaluate and compare the diagnostic ability of frequency doubling technology perimetry (FDT) with standard automated perimetry (SAP) using Humphrey Field Analyser for the detection of visual field defects produced by chiasmal lesions. METHODS Fifteen patients with documented chiasmal disease and previously diagnosed of bitemporal hemianopia with Humphrey perimetry were prospectively evaluated. All of them underwent a new SAP (SITA 24-2) followed by FDT tests (C-20 threshold). Diagnostic criteria for hemianopia were established according to the total deviation plot and the threshold values of FDT. A patient was diagnosed with hemianopia if one or both criteria were met. Based on these criteria, FDT sensitivity was calculated. Testing time and global indexes for both perimetric strategies were compared. RESULTS The sensitivity of FDT was 75.0% (18 out of 24 eyes); the criterion based on threshold values was met more often (70.83%) than the criterion based on the total deviation plot (50.0%). Linear correlation was better for the external column than for the internal column of the visual field. Testing time with FDT was 122.16 seconds shorter than with SAP (p<0.001). The mean value for mean deviation (MD) was -13.62 dB (SD 6.88) for SAP and -8.83 dB (SD 5.94) for FDT (p<0.001). CONCLUSIONS Compared with standard automatic perimetry, FDT has a low sensitivity for detecting temporal hemianopias and also has more difficulty in defining the vertical limits of the defects. Therefore, it does not appear to be an adequate method for the detection of chiasmal visual field defects.
منابع مشابه
A Comparison of the Effects of Neutral Density Filters and Diffusing Filters on Motion Detection Perimetry, White-on-white Perimetry and Frequency Doubling Perimetry
Background: Motion detection perimetry and frequency doubling perimetry are methods that have been developed with the goal of detecting glaucomatous field defects earlier than conventional white-on-white perimetry. It is well recognized that the development of cataract and pupillary constriction can significantly influence perimetric thresholds when screening for, or following the progression o...
متن کاملA comparison of perimetric results with the Medmont and Humphrey perimeters.
BACKGROUND The Humphrey field analyser (HFA), Humphrey-Zeiss frequency doubling perimeter, and the Medmont automated perimeter (MAP) are three commonly used automated perimeters with threshold achromatic methodologies. Visual field loss may be detected earlier with strategies that target cell lines with reduced redundancy or which suffer selective damage. METHOD To compare these three perimet...
متن کاملFrequency doubling perimetry in patients with mild and moderate pituitary tumor-associated visual field defects detected by conventional perimetry.
PURPOSE To test the ability of frequency doubling technology (FDT) perimetry to identify pituitary tumor-associated visual field defects. METHODS Twenty-three eyes from patients with pituitary tumor (PT) and 28 normal eyes were studied. Subjects were eligible when presenting with normal visual acuity and mild or moderate temporal field loss in at least one eye on Goldmann and standard automat...
متن کاملTest-retest variability of frequency-doubling perimetry and conventional perimetry in glaucoma patients and normal subjects.
PURPOSE To compare the test-retest variability characteristics of frequency-doubling perimetry, a new perimetric test, with those of conventional perimetry in glaucoma patients and normal control subjects. METHODS The study sample contained 64 patients and 47 normal subjects aged 66.16+/-11.86 and 64.26+/-7.99 years (mean +/- SD), respectively. All subjects underwent frequency-doubling perime...
متن کاملFrequency doubling technology perimetry for detection of glaucomatous visual field loss.
PURPOSE To evaluate the ability of frequency doubling technology perimetry to detect early, moderate, and advanced glaucomatous visual field loss. METHODS In a prospective study, frequency doubling technology perimetry (C-20 full threshold) was performed in the right eye of 254 normal control subjects and 230 patients with early (n = 85), moderate (n = 114), or advanced (n = 31) glaucomatous ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of ophthalmology
دوره 15 6 شماره
صفحات -
تاریخ انتشار 2005