Impact of remote monitoring on reducing the burden of inappropriate shocks related to implantable cardioverter-defibrillator lead fractures: insights from a French single-centre registry.

نویسندگان

  • Zouheir Souissi
  • Laurence Guédon-Moreau
  • Stéphane Boulé
  • Claude Kouakam
  • Loïc Finat
  • Christelle Marquié
  • François Brigadeau
  • Ludivine Wissocque
  • Stéphanie Mouton
  • David Montaigne
  • Didier Klug
  • Salem Kacet
  • Dominique Lacroix
چکیده

AIMS Lead fractures in implantable cardioverter-defibrillator (ICD) patients may cause inappropriate shocks (ISs). An early diagnosis is essential to prevent adverse clinical events. Implantable cardioverter-defibrillator remote monitoring (RM) permits prompt detection of lead fracture. Limited data define the impact of RM on ISs specifically related to lead fracture. We sought to compare the number of ISs related to lead fracture in patients with vs. without RM follow-up. METHODS AND RESULTS We checked the registry of our institution and collected, between July 2007 and June 2014, 115 cases of right ventricular lead fractures. All relevant data were documented from patients' files, device-interrogation printouts and electronic records, and remote transmissions databases when applicable. We assessed the ISs that were related to lead fracture. The first study endpoint was the number of ISs per shocked patient. Among the 82 patients with conventional follow-up (CFU) and the 33 patients with RM, a first IS occurred to 32.9% (n = 27) and 30.3% (n = 10, P = 0.83) of the patients, respectively. Shocked patients in the RM group underwent significantly fewer ISs with a mean of 6 ± 2 shocks per patient [median of 3.5 shocks (2-8)] than those in the CFU group with a mean of 18 ± 5 shocks per patient [median of 10 shocks (5-22), P = 0.03]. CONCLUSION Remote monitoring helps to reduce the burden of ISs related to ICD lead fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Downloadable algorithm to reduce inappropriate shocks caused by fractures of implantable cardioverter-defibrillator leads.

BACKGROUND The primary method for monitoring implantable cardioverter-defibrillator lead integrity is periodic measurement of impedance. Sprint Fidelis leads are prone to pace-sense lead fractures, which commonly present as inappropriate shocks caused by oversensing. METHODS AND RESULTS We developed and tested an algorithm to enhance early identification of lead fractures and to reduce inappr...

متن کامل

Healthcare Utilization and Expenditures Associated With Appropriate and Inappropriate Implantable Defibrillator Shocks.

BACKGROUND In patients with implantable cardioverter-defibrillators, healthcare utilization (HCU) and expenditures related to shocks have not been quantified. METHODS AND RESULTS We performed a retrospective cohort study of patients with implantable cardioverter-defibrillators identified from commercial and Medicare supplemental claims databases linked to adjudicated shock events from remote ...

متن کامل

Current clinical evidence for remote patient management.

Pacemaker (PM) and implantable cardioverter defibrillator (ICD) patients are ideally suited to remote management in the form of remote follow-up as well as of remote monitoring, which are both acts of telemedicine. Large randomized trials, such as TRUST, COMPAS, CONNECT, ECOST and EVOLVO, and the huge ALTITUDE registry provided a high level of evidence for the multiple advantages of remote mana...

متن کامل

Arrhythmia/Electrophysiology Downloadable Software Algorithm Reduces Inappropriate Shocks Caused by Implantable Cardioverter-Defibrillator Lead Fractures A Prospective Study

Background—Downloadable software upgrades are common in consumer electronics but not in implantable medical devices. Fractures of implantable cardioverter-defibrillator (ICD) leads present commonly as inappropriate shocks. A lead-integrity alert (LIA) designed to reduce inappropriate shocks is the first software download approved to enhance nominally functioning, previously implanted ICDs. Meth...

متن کامل

Outcome after implantation of a cardioverter-defibrillator in patients with Brugada syndrome: a multicenter study-part 2.

BACKGROUND Implantable cardioverter-defibrillator indications in Brugada syndrome remain controversial, especially in asymptomatic patients. Previous outcome data are limited by relatively small numbers of patients or short follow-up durations. We report the outcome of patients with Brugada syndrome implanted with an implantable cardioverter-defibrillator in a large multicenter registry. METH...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 18 6  شماره 

صفحات  -

تاریخ انتشار 2016