Remodeling of in-stent neointima, which became thinner and transparent over 3 years: serial angiographic and angioscopic follow-up.
نویسندگان
چکیده
BACKGROUND Recently, it has been reported that the luminal diameter shows phasic changes after stenting: the progression of luminal narrowing followed by its regression. To elucidate the mechanisms involved in the phasic changes in luminal diameter after stenting, we examined the changes in neointimal thickness and the appearance of neointima by a series of angiographic and angioscopic observations for 3 years after stent implantation. METHODS AND RESULTS In 12 patients who received a Wiktor coronary stent, serial angiographic and angioscopic examinations were performed immediately, 2 to 4 weeks, 3 months, 6 months, and 3 years after the stenting without repetition of angioplasty. Neointimal thickness was determined by angiography as the difference between stent and luminal diameters. The angioscopic appearance of neointima over the stent was classified as transparent or nontransparent according to the visibility of the majority of the stent. Neointimal thickness increased significantly at 3 months (0.75+/-0.32 mm) without further changes at 6 months (0.74+/-0.32 mm). Thereafter, however, it decreased significantly over 3 years (0.51+/-0.26 mm). The angioscopic appearance was classified as transparent in 8 patients (100) immediately after stenting, 6 patients (100%) at 2 to 4 weeks, 2 patients (17%) at 3 months, 2 patients (20%) at 6 months, and 7 patients (58%) at 3 years. CONCLUSIONS The neointima became thick and nontransparent until 6 months and then became thin and transparent by 3 years. We conclude that neointimal remodeling exists after stenting and plays a major role in the alteration of coronary luminal diameter after stenting.
منابع مشابه
Extended follow-up by serial angioscopic observation for bare-metal stents in native coronary arteries: from healing response to atherosclerotic transformation of neointima.
BACKGROUND Although coronary angiograms after bare-metal stent (BMS) implantation show late luminal narrowing beyond 4 years, the detailed changes inside the BMS have not yet been fully elucidated. METHODS AND RESULTS Serial angiographic and angioscopic examinations were performed immediately (baseline), 6 to 12 months (first follow-up), and >or=4 years (second follow-up) after stenting witho...
متن کاملSafety, Efficacy and Clinical Outcome of Direct Stent Implantation
Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...
متن کاملSerial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation: comparison with bare-metal stents.
BACKGROUND The time course of neointimal formation after stent implantation has not been studied extensively by angioscopy in the drug-eluting stent era. METHODS AND RESULTS Serial angioscopic findings at first follow-up (3.6+/-1.1 months), second follow-up (10.5+/-1.6 months), and third follow-up (21.2+/-2.2 months) after stent implantation were compared between sirolimus-eluting stents (SES...
متن کاملLack of association between large angiographic late loss and low risk of in-stent thrombus: angioscopic comparison between paclitaxel- and sirolimus-eluting stents.
BACKGROUND It recently has been hypothesized that a larger late loss may have a protective role against stent thrombosis. The relationship between angiographic late loss and the presence of thrombus based on angioscopic findings within paclitaxel-eluting stents (PES) and sirolimus-eluting stents (SES) was investigated in this study. METHODS AND RESULTS Prospective 6-month follow-up angiograph...
متن کاملAtherosclerotic and thrombogenic neointima formed over sirolimus drug-eluting stent: an angioscopic study.
OBJECTIVES We sought to examine by angioscopy the neointima formation and thrombogenic potential of the neointima after deployment of a drug-eluting stent (DES). BACKGROUND Late stent thrombosis after DES implantation, a major safety concern, has been associated with poor strut coverage by neointima. Intracoronary angioscopy provides a method for visual evaluation of stent coverage by neointi...