Evaluation of Analytical Errors in a Clinical Chemistry Laboratory: A 3 Year Experience

نویسندگان

  • AS Sakyi
  • EF Laing
  • RK Ephraim
  • OF Asibey
  • OK Sadique
چکیده

BACKGROUND Proficient laboratory service is the cornerstone of modern healthcare systems and has an impact on over 70% of medical decisions on admission, discharge, and medications. In recent years, there is an increasing awareness of the importance of errors in laboratory practice and their possible negative impact on patient outcomes. AIM We retrospectively analyzed data spanning a period of 3 years on analytical errors observed in our laboratory. The data covered errors over the whole testing cycle including pre-, intra-, and post-analytical phases and discussed strategies pertinent to our settings to minimize their occurrence. MATERIALS AND METHODS We described the occurrence of pre-analytical, analytical and post-analytical errors observed at the Komfo Anokye Teaching Hospital clinical biochemistry laboratory during a 3-year period from January, 2010 to December, 2012. Data were analyzed with Graph Pad Prism 5(GraphPad Software Inc. CA USA). RESULTS A total of 589,510 tests was performed on 188,503 outpatients and hospitalized patients. The overall error rate for the 3 years was 4.7% (27,520/58,950). Pre-analytical, analytical and post-analytical errors contributed 3.7% (2210/58,950), 0.1% (108/58,950), and 0.9% (512/58,950), respectively. The number of tests reduced significantly over the 3-year period, but this did not correspond with a reduction in the overall error rate (P = 0.90) along with the years. CONCLUSION Analytical errors are embedded within our total process setup especially pre-analytical and post-analytical phases. Strategic measures including quality assessment programs for staff involved in pre-analytical processes should be intensified.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of errors in a clinical laboratory: a one-year experience.

BACKGROUND Efficient laboratory service is the cornerstone of modern health care systems. Scientific innovations have contributed to substantial improvements in the field of laboratory science, but errors still prevail. These errors are classified as preanalytical, analytical and postanalytical, depending upon the time of presentation. METHODS The data for 67,438 routine venous blood specimen...

متن کامل

Frequency of Errors in Clinical Laboratory Practice

  Background and Objective: Laboratory errors are one of the major factors that affect the diagnosis, prognosis, treatment and monitoring in patients.The objective of study is to evaluate the frequency and type of errors in different phases of testing at the Pathology Department of the Shalamar Hospital, Lahore and to evaluate the causes of errors. Methods: This observational study was carrie...

متن کامل

Evaluation of biochemical methods performance in clinical laboratories: is this performance suitable for clinical application?

Background: Clinical application of the test results are profoundly influenced by laboratory errors. Nowadays, the best way to evaluate the performance of a method is to determine its sigma scale according to total allowable error (TEa) and analytical errors, including random and systematic errors. In this study, the performance of the measuring kits for biochemical analytes belonging to Pars A...

متن کامل

نوع و میزان خطای انسانی در کارکنان بخش پذیرش و جواب دهی آزمایشگاههای تشخیص طبی شهرهای تهران و تبریز طی سال 1393

Background and aims: The importance of clinical laboratories work and test results is clearly related with the community health. This study aimed to evaluate the variety and rate of Pre and Post-Analytical errors among reception staff in clinical laboratories of governmental, private and military hospitals. Methods: In this cross-sectional descriptive study, 183 of reception staff of clinica...

متن کامل

Error tracking in a clinical biochemistry laboratory.

BACKGROUND We report our results for the systematic recording of all errors in a standard clinical laboratory over a 1-year period. METHODS Recording was performed using a commercial database program. All individuals in the laboratory were allowed to report errors. The testing processes were classified according to function, and errors were classified as pre-analytical, analytical, post-analy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015