An in vitro investigation of wear resistance and hardness of composite resins.

نویسندگان

  • Liqun Cao
  • Xinyi Zhao
  • Xu Gong
  • Shouliang Zhao
چکیده

PURPOSE The aim of the present study was to investigate the wear resistance and hardness of five kinds of composite resins. MATERIALS AND METHODS Sixty-five specimens were fabricated with one nano-hybrid (Charisma Diamond), two micro-hybrid (3MZ250, Clearfil AP-X) and two packable (3MP60, Surefil) composite resins, according to a randomized complete block design (n=13, 8 for wear test; 5 for hardness test). The composites were filled in a rectangular mold, and light polymerization. After storage in 37°C deionized water for 24h, all specimens were tested with a custom-made toothbrush machine with a stainless-steel ball as antagonist (3N loads, 1Hz, 6×10(5) cycles) immersed in calcium fluoride slurry. Wear volume, hardness and surface structure of each tested material was examined by a three-dimensional non-contact optical profilometer, Vickers indentation technique and scanning electron microscope. RESULTS The volume loss ranked from least to most as follows: Charisma Diamond, P60, Z250, Clearfil AP-X and Surefil. Regarding hardness, the rank from highest to lowest as follows: Clearfil AP-X, P60, Surefil, Z250, Charisma Diamond. The interactions between wear resistance and microhardness were not significant. CONCLUSIONS The custom-made machine is considered suitable to simulate sliding of an antagonist cusp on an opposing occlusal composite restoration. Nanofilled composite may have superior wear compared to other composite resins.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wear test of composite restorative materials by a polishing machine.

The wear resistance of microfilled and conventional composite resins, was examined, using two sizes of abrasive particles for polishing. The mechanical properties of the composite resins were also studied and evaluated in relation to wear. Conventional composites showed much lower wear resistance than the microfilled resins. The amalgam and human enamel abraded with 10ƒÊm SiC particles, had str...

متن کامل

Wear of opposing teeth by posterior composite resins--evaluation of newly developed wear test methods.

In the present study, enamel wear against indirect composite resins was evaluated using two newly designed wear test methods: a rotating sliding wear test and a buff wear test. For the composite resins investigated in this study, their surface morphologies were examined using a scanning probe microscope after buff-polishing. After the wear tests, enamel was worn down by hard fillers that protru...

متن کامل

Evaluation of hardness and wear resistance of nano-sized titanium-carbide-reinforced commercially cast aluminum alloy matrices

Production of aluminum matrix composites is widespread because these material provide enhanced mechanical properties compared to aluminum. One the most important parameters of metal matrix composite production is uniform distribution of reinforcing nanoparticles in matrices using the stir-casting method. Second is ensuring high wettability, which is determined by evaluating the properties of ma...

متن کامل

بررسی اثر نوع فیلر بر سایش سه جزئی کامپوزیت دندانی

Statement of Problem: The relatively poor wear resistance of dental composite in stress bearing posterior situations has restricted wider clinical application of this restorative material. Purpose: The aim of this study was to evaluate the three body abrasive wear of a dental composite based on a new filler (leucite: KAl Si2O6) and to compare it with the wear resistance of a composite based on ...

متن کامل

The effect of TiO2 concentration on microstructure, corrosion behavior and wear behavior of Ni-P-W-TiO2 coating

Nickel-phosphorus coatings (Ni-P) are widely used in industry due to their high hardness, corrosion resistance and very good mechanical and chemical properties. Oxide particles such as TiO2 can be used to increase the wear resistance of these coatings. In this study, the Ni-P-W-TiO2 composite coating was deposited on the AISI 304L steel substrate using the electroplating method. Electroplating ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of clinical and experimental medicine

دوره 6 6  شماره 

صفحات  -

تاریخ انتشار 2013