A BINOL-based ratiometric fluorescent sensor for Zn2+ and in situ generated ensemble for selective recognition of histidine in aqueous solution.
نویسندگان
چکیده
A novel BINOL-based ratiometric fluorescent sensor (R2) is presented, which can selectively respond to Zn(2+) over Cd(2+) and other metal ions with fluorescence enhancement in aqueous solution. The R2 was successfully applied in the imaging of Zn(2+) in living cells. Additionally, the in situ generated R2-Zn(II) ensemble could further serve as a probe to distinguish histidine from other amino acids via a displacement mode.
منابع مشابه
Cd(II)-terpyridine-based complex as a ratiometric fluorescent probe for pyrophosphate detection in solution and as an imaging agent in living cells.
The terpyridine anthracene ligand was synthesized and characterized. is a ratiometric fluorescent probe for Cd(2+) with a recognition mechanism based on intramolecular charge transfer (ICT). An complex was isolated, and its structure was established using single-crystal XRD. The complex was able to serve as a novel reversible chemosensing ensemble to allow ratiometric response to pyrophosphate ...
متن کاملA ratiometric fluorescent sensor for phosphates: Zn2+-enhanced ICT and ligand competition.
A pyrene-terpyridine-Zn conjugate has been synthesized and characterized, where Zn2+ acts as an electron acceptor to enhance molecular ICT with a large emission red-shift (>100 nm). It showed a ratiometric fluorescence change upon addition of phosphate anions in buffered aqueous solution. The selective response to phosphates or pyrophosphates involved ICT and ligand competition processes.
متن کاملA Zn2+-specific turn-on fluorescent probe for ratiometric sensing of pyrophosphate in both water and blood serum.
A novel fluorescent sensor composed of a naphthalene functionalized tetraazamacrocycle ligand 3,6,9,15-tetraazabicyclo[9.3.1]pentadeca-1(15),11,13-triene-3-methyl naphthalene (1) and Zn(2+) has been designed and prepared, which can be utilized for selective and ratiometric sensing of pyrophosphate (PPi) over other phosphate-containing anions in aqueous solution at physiological pH. Notably, the...
متن کاملA highly sensitive and selective detection of Hg(II) in 100% aqueous solution with fluorescent labeled dimerized Cys residues.
A simple design of a ratiometric fluorescent sensor for detecting Hg(II) ion in 100% aqueous solution was demonstrated, based on the structure of dimerized Cys residues with two dansyl fluorophores. The sensor highly sensitively and selectively detected mercury ion (K(d) = 41 nM) in 100% aqueous solution via a turn-on and ratiometric response. The sensor showed no interferences of other metal i...
متن کاملRatiometric and highly selective fluorescent sensor for cadmium under physiological pH range: a new strategy to discriminate cadmium from zinc.
In a neutral aqueous environment, a new ratiometric Cd2+ fluorescent sensor 1a can successfully discriminate Cd2+ from Zn2+ by undergoing two different internal charge transfer (ICT) processes, and the high selectivity of sensor 1a to Cd2+ over some other metals was also observed. Moreover, through structure derivation and a series of NMR studies, the unique role of the 2-picolyl group (the par...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Analyst
دوره 138 19 شماره
صفحات -
تاریخ انتشار 2013