Assessment of microcirculatory remodeling with intracoronary flow velocity and pressure measurements: validation with endomyocardial sampling in cardiac allografts.
نویسندگان
چکیده
BACKGROUND Intracoronary physiology techniques have been validated extensively for the assessment of epicardial stenoses but not for the lone study of coronary microcirculation. We performed a comparison between 4 intracoronary physiological indices with the actual structural microcirculatory changes documented in transplanted hearts. METHODS AND RESULTS In 17 cardiac allograft patients without coronary stenoses, ECG, intracoronary Doppler flow velocity, and aortic pressure were digitally recorded before and during maximal hyperemia with a dedicated system. Postprocessing of data yielded 4 indices of microcirculatory status: coronary flow velocity reserve (2.13+/-0.59), instantaneous hyperemic diastolic velocity pressure slope (2.33+/-1.25 cm x s x (-1)mm Hg(-1)), coronary resistance index (1.65+/-0.88 mm Hg x cm(-1) x s(-1)), and coronary resistance reserve (2.36+/-0.65). Quantitative morphometry was performed in endomyocardial biopsies during the same hospital intake; arteriolar obliteration (76.57+/-6.95%) and density (2.00+/-1.22 arterioles per 1 mm(2)) and capillary density (645+/-179 capillaries per 1 mm(2)) were measured. Univariate regression analysis between intracoronary measurements and histological findings revealed that instantaneous hyperemic diastolic velocity-pressure slope correlated with arteriolar obliteration (r=0.58, P=0.014) and capillary density (r=0.60, P=0.012). Statistical adjustment revealed an independent contribution of arteriolar obliteration (beta=0.61, P=0.0009) and capillary density (beta=-0.60, P=0.0008) to instantaneous hyperemic diastolic velocity-pressure slope values, resulting in an excellent predictive model (r=0.84, P=0.0002). Coronary resistance index correlated only with capillary density (r=0.70, P=0.019). Relative indices (coronary flow velocity reserve and coronary resistance reserve) did not correlate significantly with arteriolar obliteration, capillary density, or arteriolar density. CONCLUSIONS Intracoronary indices derived from pressure and flow, particularly instantaneous hyperemic diastolic velocity-pressure slope, appear to be superior to coronary flow velocity reserve in detecting structural microcirculatory changes. Both arteriolar obliteration and capillary rarefaction seem to influence microcirculatory hemodynamics independently.
منابع مشابه
Magnetic Resonance for Noninvasive Detection of Microcirculatory Disease Associated With Allograft Vasculopathy: Intracoronary Measurement Validation.
INTRODUCTION AND OBJECTIVES Cardiac allograft vasculopathy affects both epicardial and microcirculatory coronary compartments. Magnetic resonance perfusion imaging has been proposed as a useful tool to assess microcirculation mostly outside the heart transplantation setting. Instantaneous hyperemic diastolic flow velocity-pressure slope, an intracoronary physiology index, has demonstrated a bet...
متن کاملIntracoronary Delivery of Human Mesenchymal/Stromal Stem Cells: Insights from Coronary Microcirculation Invasive Assessment in a Swine Model
BACKGROUND Mesenchymal stem/stromal cells have unique properties favorable to their use in clinical practice and have been studied for cardiac repair. However, these cells are larger than coronary microvessels and there is controversy about the risk of embolization and microinfarctions, which could jeopardize the safety and efficacy of intracoronary route for their delivery. The index of microc...
متن کاملInvasive minimal Microvascular Resistance Is a New Index to Assess Microcirculatory Function Independent of Obstructive Coronary Artery Disease
BACKGROUND Coronary microcirculatory dysfunction portends a poor cardiovascular outcome. Invasive assessment of microcirculatory dysfunction by coronary flow reserve (CFR) and hyperemic microvascular resistance (HMR) is affected by coronary artery disease (CAD). In this study we propose minimal microvascular resistance (mMR) as a new measure of microcirculatory dysfunction and aim to determine ...
متن کاملCFD Modeling of TiO2 Nano-Agglomerates Hydrodynamics in a Conical Fluidized Bed Unit with Experimental Validation
In the computational fluid dynamics (CFD) modeling of gas-solids two phase flow, the effect of boundary conditions play an important role in predicting the hydrodynamic characteristics of fluidized beds. In this work, the hydrodynamics of conical fluidized bed containing dried TiO2 nano-agglomerates were studied both experimentally and computationally. The pressure drop ...
متن کاملUtilization of translesional hemodynamics: comparison of pressure and flow methods in stenosis assessment in patients with coronary artery disease.
Aim of this study is the assessment of feasibility and clinical usefulness of a new index of stenosis severity, the slope of the instantaneous transstenotic pressure gradient/velocity relationship. Twenty-one patients scheduled for percutaneous revascularization procedures were studied with simultaneous measurement of poststenotic coronary pressure and flow velocity, in basal condition and duri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 120 16 شماره
صفحات -
تاریخ انتشار 2009