Use of a silicon drift detector for cathodoluminescence detection
نویسنده
چکیده
منابع مشابه
Avalanche Amplification in Silicon Drift Detectors
A novel device which combines advantages of Silicon Drift Detector and Silicon Avalanche Diode on the same silicon wafer is proposed. Avalanche ampliication is applied to cloud of drifting electrons in order to improve detection of radiation with low energy deposition coeecient. Principle and optimal conditions for the operation of this new detector based on Avalanche Ampliier are discussed.
متن کاملCommissioning of the Silicon Drift Detectors of the ALICE experiment at the LHC
Silicon Drift Detectors (SDD) equip the two central layers of the Inner Tracking System of the ALICE experiment at the LHC. Main results of systematic studies of detector performance including noise, gain, drift speed and charge collection measurements will be reported. 1 ALICE experiment and SDD module Silicon Drift Detectors (SDD) [1] offer two-dimensional position reconstruction with a limit...
متن کاملSilicon Lithium Detectors for Synchrotron Energy Dispersive X-Ray Fluorescence Spectroscopy
Introduction Detector description and its principle of operation Detector module. Detector Features and its Performance EDXRF of Fe 55 Spectrum Detector comparison with Silicon Drift Detector SDD Concluding remarks References A Silicon Lithium Si(Li) detector is presented. The detector structure and its working principle are explained. The detector is cooled to 77o K by liquid Nitrogen. The det...
متن کاملSimulation and Fabrication of Gated Silicon Drift X-Ray Detector Operated by Peltier Cooling
A proposed simply structured gated silicon (Si) drift X-ray detector operated using Peltier cooling and only a single high-voltage source is investigated. Because the device structure is much simpler than that of commercial Si drift detectors (SDDs), which require at least two high-voltage sources, the cost of the X-ray detection system can be reduced. The absorption of cadmium X-ray fluorescen...
متن کاملA Double Silicon Drift Type Detector System for EDS with Ultrahigh Efficiency and Throughput for TEM
For elemental analysis with energy dispersive X-ray spectroscopy (EDS) in transmission electron microscopy (TEM), the demand for the improved efficiency of X-ray detection, a higher counting rate, is very strong, because the improvement not only results in high throughput, but also extends the method to the specimens fairly susceptible to electron beam damage. We have already developed and intr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Microelectronics Reliability
دوره 55 شماره
صفحات -
تاریخ انتشار 2015