Assessment of global left ventricular function and volumes with 320-row multidetector computed tomography: A comparison with 2D-echocardiography
نویسندگان
چکیده
BACKGROUND Multidetector computed tomography (MDCT) has been demonstrated as a feasible imaging modality for noninvasive assessment of coronary artery disease and left ventricular (LV) function. Recently, 320-row systems have become available with 16 cm anatomical coverage allowing image acquisition of the entire heart within a single heartbeat. The purpose of this study was to evaluate the accuracy of 320-row MDCT in the assessment of global LV function compared to two-dimensional (2D) echocardiography as the standard of reference. METHODS AND RESULTS A head-to-head comparison between 320-row MDCT and 2D-echocardiography was performed in 114 patients (68 men; mean age 62 +/- 13 years) who were clinically referred for MDCT coronary angiography. The entire heart was imaged in a single heartbeat, using prospective dose modulation. LV end-diastolic volumes (LVEDV) and LV end-systolic volumes (LVESV) were determined and the LV ejection fraction (LVEF) was derived. Average LVEF was 60 +/- 10% (range 26-78%) as determined on MDCT, compared with 59 +/- 10% (range 25-77%) on 2D-echocardiography. Evaluation of LVEF by linear regression analysis showed a good correlation between MDCT and 2D-echocardiography (r(2) = .87; P < .001). Good correlations between MDCT and 2D-echocardiography were demonstrated for the assessment of LVEDV (r(2) = .91; P < .001) and LVESV (r(2) = .94; P < .001). At Bland-Altman analysis, mean differences (+/-SD) of 7.3 +/- 12.1 mL (P < .05) and 1.8 +/- 7.4 mL (P < .05) were observed between MDCT and 2D-echocardiography for LVEDV and LVESV, respectively. LVEF was slightly overestimated with MDCT (.9 +/- 3.6%; P < .05). CONCLUSIONS Accurate assessment of LV function and volumes is feasible with single heartbeat 320-row MDCT in patients referred for MDCT coronary angiography.
منابع مشابه
Global and regional left ventricular function assessment with 16-detector row CT: comparison with echocardiography and cardiovascular magnetic resonance.
AIMS To compare multidetector row computed tomography (MDCT) global and regional left ventricular (LV) function assessment with echocardiography and cardiovascular magnetic resonance (CMR). METHODS AND RESULTS In 25 patients, who were referred for noninvasive angiography with 16-detector row CT, LV function assessment was also performed. A subsequent echocardiogram was performed, and in a sub...
متن کاملMultiple atrial septal defects in multidetector-row computed tomography.
A 70-year-old-man was referred to our hospital for percutaneous closure of a secundum atrial septal defect (ASD). His transthoracic echocardiography (TTE) showed 2 left-to-right ASDs with a pulmonary/systemic flow ratio (Q p/Q s) of 1.89 and normal left ventricular function. Cardiac computed tomography (CT) using 320-detector row CT (Aquilion ONE VISION edition, Toshiba Medical Systems, Tokyo, ...
متن کاملAssessment of global and regional left ventricular function and volumes with 64-slice multi-slice computed tomography: a comparison with 2D echocardiography
Introduction: In patients with coronary artery disease (CAD), LV function and volumes are important parameters for long-term prognosis. 64-slice MSCT allows non-invasive assessment of the coronary arteries, but the accuracy of 64-slice MSCT for assessment of LV volumes and function is unknown. Methods: A head-to-head comparison between 64-slice MSCT and 2D echocardiography was performed in 40 p...
متن کاملHead-to-Head Comparison of Left Ventricular Function Assessment with 64-Row Computed Tomography, Biplane Left Cineventriculography, and Both 2- and 3-Dimensional Transthoracic Echocardiography
Results For the global EF, Bland-Altman analysis showed significantly higher agreement between CT and MRI (p 0.005, 95% confidence interval: 14.2%) than for CVG ( 20.2%) and 3D Echo ( 21.2%). Only CVG (59.5 13.9%, p 0.03) significantly overestimated EF in comparison with MRI (55.6 16.0%). CT showed significantly better agreement for stroke volume than 2D Echo, 3D Echo, and CVG. In comparison wi...
متن کاملHigh myocardial 18F-FDG uptake after chemotherapy in the presence of left ventricular dysfunction as well as 3-month later with no left ventricular dysfunction
Diffusely increased glucose metabolic activity in the right and left ventricles using 2-deoxy-2-(F-18) fluoro-D-glucose positron emission tomography/computed tomography (18F-FDGPET/CT) and global left ventricular hypokinesia at echocardiography can be evident in acute myocarditis. But, there has been no case report that the ventricular 18F-FDGuptake remains unchanged even ...
متن کامل