Fluid and structure coupling analysis of the interaction between aqueous humor and iris
نویسندگان
چکیده
BACKGROUND Glaucoma is the primary cause of irreversible blindness worldwide associated with high intraocular pressure (IOP). Elevated intraocular pressure will affect the normal aqueous humor outflow, resulting in deformation of iris. However, the deformation ability of iris is closely related to its material properties. Meanwhile, the passive deformation of the iris aggravates the pupillary block and angle closure. The nature of the interaction mechanism of iris deformation and aqueous humor fluid flow has not been fully understood and has been somewhat a controversial issue. The purpose here was to study the effect of IOP, localization, and temperature on the flow of the aqueous humor and the deformation of iris interacted by aqueous humor fluid flow. METHODS Based on mechanisms of aqueous physiology and fluid dynamics, 3D model of anterior chamber (AC) was constructed with the human anatomical parameters as a reference. A 3D idealized standard geometry of anterior segment of human eye was performed. Enlarge the size of the idealization geometry model 5 times to create a simulation device by using 3D printing technology. In this paper, particle image velocimetry technology is applied to measure the characteristic of fluid outflow in different inlet velocity based on the device. Numerically calculations were made by using ANSYS 14.0 Finite Element Analysis. Compare of the velocity distributions to confirm the validity of the model. The fluid structure interaction (FSI) analysis was carried out in the valid geometry model to study the aqueous flow and iris change. RESULTS In this paper, the validity of the model is verified through computation and comparison. The results indicated that changes of gravity direction of model significantly affected the fluid dynamics parameters and the temperature distribution in anterior chamber. Increased pressure and the vertical position increase the velocity of the aqueous humor fluid flow, with the value increased of 0.015 and 0.035 mm/s. The results act on the iris showed that, gravity direction from horizontal to vertical decrease the equivalent stress in the normal IOP model, while almost invariably in the high IOP model. With the increased of the iris elasticity modulus, the equivalent strain and the total deformation of iris is decreased. The maximal value of equivalent strain of iris in high IOP model is higher than that of in normal IOP model. The maximum deformation of iris is lower in the high IOP model than in the normal IOP model. CONCLUSION The valid model of idealization geometry of human eye could be helpful to study the relationship between localization, iris deformation and IOP. So far the FSI analysis was carried out in that idealization geometry model of anterior segment to study aqueous flow and iris change.
منابع مشابه
Erratum to: Fluid and structure coupling analysis of the interaction between aqueous humor and iris
© The Author(s) 2017. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License(http:// creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium,provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, andindicate if cha...
متن کاملModeling passive mechanical interaction between aqueous humor and iris.
Certain forms of glaucoma are associated with displacement of the iris from its normal contour. We present here a mathematical model of the coupled aqueous humor-iris system that accountsfor the contribution of aqueous humor flow and passive iris deformability to the iris contour. The aqueous humor is modeled as a Newtonian fluid, and the iris is modeled as a linear elastic solid. The resulting...
متن کاملAccommodative microfluctuations and iris contour.
Mechanical interaction between aqueous humor, iris, and intraocular structures can alter the iris profile from its normal curvature. In particular, significant changes to the iris profile occur during accommodation as the anterior lens movement forces the iris into greater posterior bowing. We extended a previous mathematical model of the anterior segment and investigated the response of this c...
متن کاملUnder Pressure: Canine and Feline Glaucoma
Aqueous humor (AH) is the fluid that fills the anterior chamber of the eye. This fluid is produced by the epithelial cells of the ciliary body, flows through the pupil, and circulates in the anterior chamber. Aqueous humor is optically clear, but contains various compounds such as carbohydrates, amino acids, glucose, lactate, small proteins, ions, and urea, which provide the nutritional support...
متن کاملNumerical Analysis of the Thermal Interaction of Cell Phone Radiation with Human Eye Tissues
Introduction: The present study aimed to present a numerical analysis of the penetration depth, specific absorption rate (SAR), and temperature rise in various eye tissues with varying distance between radiation source and exposed human eye tissues (i.e., cornea, posterior chamber, anterior chamber, lens, sclera, vitreous humor, and iris) at frequencies of 900 and1800 MHz. Materials and Method...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2016