Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load
نویسندگان
چکیده
An experimental rig has been built to test a horizontal scroll compressor and a reciprocating compressor of similar size and capacity. The compressors were tested with refrigerant.R404A operating at varying evaporator and condenser temperatures. The paper provides much needed information regarding the efficiency of the compressors operating under the same conditions with the same system parameters. This paper also reports on investigations being carried out on the effect of refrigerant charge on both types of compressor. The results show that the scroll compressor generally produces cooling capacities and COPs that are equal to or greater than the reciprocating compressor. Both compressor types exhibit the same general characteristics with respect to system charge. In particular, COP is reduced with significant underand over-charging. Superheat and subcooling are shown to be functions of system charge level for both compressors and thus may be used as a general indicator of charge level, irrespective of the compressor type. INTRODUCTION The scroll compressor has gained wide acceptance in recent years in commercial applications. The compactness and lightweight of scrolls along with apparent low sound and vibration level has made them very popular. One of the scroll compressor advantages is that the number of moving components is very low compared to reciprocating compressors. Also, it is reported that the volumetric and isentropic efficiencies are higher than similar sizes of reciprocating compressors. However, little information is available on how well it compares in performance with an equal size reciprocating compressor under similar load variation and refrigerant charge variation which can be useful when replacing reciprocating compressors with scroll compressors. The use of scroll compressor in supermarket packs which serve remote display cabinets have become widespead in the UK, (Hundy 1998). However, because of the height of the vertical scrolls they are yet to replace the small reciprocating compressors used in integral cabinets. Hence a horizontal scroll was used in order to establish its operation characteristics and evaluate whether it will be able to easily replace reciprocating compressors in integral display cabinets.
منابع مشابه
Numerical Study and Experimental Comparison of CO2 Reciprocating Compressors for Small Cooling and/or Freezing Capacity Applications
The present paper is a numerical and experimental comparative study of hermetic and semi-hermetic reciprocating compressors working with carbon dioxide as fluid refrigerant against the conventional R134a hermetic compressors. When cooling conditions for one-stage compressor type (i.e., evaporation temperatures between 7.2oC and –10oC) have been considered, the numerical and experimental results...
متن کاملDevelopment of Large Capacity CO2 Scroll Compressor
CO2 refrigerant with a high operating pressure has a large difference between the suction and discharge pressures in compressors. Because of a load increase, the high performance and high reliability of compressors are required. Compared to the scroll compressor employing the conventional refrigerant, the thrust load increases in the CO2 scroll compressor. Therefore the design of thrust bearing...
متن کاملDischarge Gas Temperature Control in Reciprocating Hermetic Compressors Modified for R134a/R22 Refrigerants Operation as Substitutes of Present R12/R502
Discharge gas temperature value is an indicator of compressor safe operating conditions, particularly on R12 and R502 commercial applications. These refrigerants will be replaced very soon by R134a and R22 respectively, also if R22 is not considered a final solution. High discharge temperatures are typical in LBP-R22 hermetic compressors operating at low evaporating temperature as low as -40"C;...
متن کاملThermal Analysis of a Hermetic Reciprocating Compressor
The development of more efficient hermetic compressors for refrigeration involves a sound analysis of the heat exchanges inside the machine to evaluate the interaction among compressor structure, flow characteristics, refrigerant properties and operative conditions. This work presents a computational procedure for the steady-state thermal analysis of a hermetic reciprocating compressor. The mac...
متن کاملAdvanced Numerical Simulation Model of Hermetic Reciprocating Compressors
A complete and advanced numerical simulation model of the thermal and fluid-dynamic performance of hermetic reciprocating compressors has been developed and is used in the optimization Electrolux compressor design. During the last few years several global experimental validations have been carried out. A detailed instrumentation of a commercial reciprocating compressor for household refrigerato...