Stimulation map for control of functional grasp based on multi-channel EMG recordings.

نویسندگان

  • Lana Popović Maneski
  • Ivan Topalović
  • Nenad Jovičić
  • Suzana Dedijer
  • Ljubica Konstantinović
  • Dejan B Popović
چکیده

Transcutaneous activation of muscles with electrical stimulation has limited selectivity in recruiting paralyzed muscles in stroke patients. However, the selectivity could be increased by the application of smaller electrodes and their appropriate positioning on the skin. We developed a method for selecting the appropriate positions of the stimulating electrodes based on electromyography (EMG). The EMG activity maps were estimated from signals recorded with two electrode arrays and two 24-channel wearable amplifiers positioned on the nonparetic and paretic forearms. The areas where the difference between the EMG maps obtained from the nonparetic and paretic arms was significant were identified as the stimulation sites. The stimulation was applied through array electrodes with magnetic holders and two wearable stimulators with four output channels each. The measures of functionality included joint angles measured with goniometers (hand opening) and grasp force measured with a multi-contact dynamometer (grasping). The stimulation protocol comprised co-activation of flexors and extensors to stabilize the wrist joint and prevent pronation/supination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adaptive Interference Reduction in Nerve Cuff Electrode Recordings

Neural signals (ENG) recorded from insulating cuffs fitted with electrodes and placed around nerve bundles may replace artificial sensors in providing feedback signals in functional electrical stimulation (FES) applications. Typical applications include correction of foot-drop, hand grasp in tetraplegic subjects and bladder voiding in certain types of incontinence. Unfortunately, the ENG signal...

متن کامل

DSP-Based Controller for a Multi-Degree Prosthetic Hand

The electromyographic (EMG) signal is used to discriminate eight hand motions: power grasp, hook grasp, wrist flexion, lateral pinch, flattened hand, centralized grip, three-jaw chuck and cylindrical grasp. From the analysis of the PC-based control system, a three-channel EMG signal is used to distinguish eight hand motions for the short below elbow amputee. Pattern recognition is used in this ...

متن کامل

An EMG-controlled grasping system for tetraplegics.

A two-channel, portable, battery operated, functional electrical stimulation (FES) system with surface electrodes to enhance grasping in tetraplegics was developed and tested. This system is meant for tetraplegics capable of grasping by tenodesis. Candidates for this system must retain some wrist extension, and have paralyzed but innervated finger flexors, and nearly normal shoulder and elbow c...

متن کامل

Protective role of cyclosporine on the model simulated the rotational nodal arrhythmia (AVNRT) by using extracellular field potential recordings of isolated atrioventricular-node of rabbit

Introduction: Recent studies have shown acute cardioprotective effects of cyclosporine. The aim of the present study was to determine the protective role of cyclosporine on the model simulated the rotational nodal arrhythmia (AVNRT) by using extracellular field potential recordings of isolated atrioventricular-node (AV-node) of rabbit. Methods: This study was performed on isolated double-per...

متن کامل

Multi-channel EEG recordings during 3,936 grasp and lift trials with varying weight and friction

WAY-EEG-GAL is a dataset designed to allow critical tests of techniques to decode sensation, intention, and action from scalp EEG recordings in humans who perform a grasp-and-lift task. Twelve participants performed lifting series in which the object's weight (165, 330, or 660 g), surface friction (sandpaper, suede, or silk surface), or both, were changed unpredictably between trials, thus enfo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical engineering & physics

دوره 38 11  شماره 

صفحات  -

تاریخ انتشار 2016