Time variation of mitral regurgitant flow in patients with dilated cardiomyopathy.
نویسندگان
چکیده
Angiographic results in patients with mitral regurgitation suggest that up to 50% of the regurgitant volume occurs during the preejection period. This contrasts markedly with the electromagnetic measurements of mitral regurgitant flow in anesthetized dogs, which suggest that only 5% of mitral regurgitant flow occurs during the preejection period. Therefore, we used two-dimensional and Doppler echocardiography to quantify mitral regurgitation during aortic ejection and in the preejection and postejection periods in eight patients with severe heart failure. Mitral regurgitant volume (RV) was calculated as the difference between total stroke volume (by two-dimensional echocardiography) and forward aortic flow (by pulsed Doppler). Regurgitant velocity (V) and time (RT) were measured by continuous-wave Doppler, and the mean regurgitant area (RAm) was calculated from the RT and mean regurgitant velocity (Vm): RAm = (RV/RT)/Vm. As a first approximation, the RA was assumed to be constant during systole, and the regurgitant volume during aortic ejection and during the preejection and postejection periods was calculated from: RVi = (Vmi) (RTi) (TAm), where Ti represents the duration of the appropriate period. Percentages of total regurgitant volume occurring during the preejection, ejection, and postejection periods were 13 +/- 4%, 79 +/- 5%, and 8 +/- 5%, respectively. Thus, in contrast to previously reported angiographic studies, mitral regurgitation occurs predominantly during the aortic ejection period. These results were not substantially changed by assuming a 20% reduction in effective regurgitant orifice area between the preejection and ejection periods and are consistent with data from chronically instrumented dogs with mitral regurgitation.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Physiologic Application of the Proximal Flow Convergence Method: Clinical Data and Experimental Testing
Background The proximal flow convergence method, a quantitative color Doppler flow technique, has been validated recently for calculating regurgitant flow and orifice area. We investigated the potential of the method as a tool to study different pathophysiological mechanisms of mitral valve incompetence by assessing the time course of regurgitant flow and orifice area and analyzed the implicati...
متن کاملAssessment of Mitral Regurgitation Severity by Doppler Color Flow Mapping of the Vena Contracta in Dogs
BACKGROUND Although Doppler color flow mapping is widely used to assess the severity of mitral regurgitation (MR), a simple, accurate, and quantitative marker of MR by color flow mapping remains elusive. We hypothesized that vena contracta width by color flow mapping would accurately predict the severity of MR. METHODS AND RESULTS We studied 80 patients with MR. Vena contracta width was measu...
متن کاملDynamics of mitral regurgitant flow and orifice area. Physiologic application of the proximal flow convergence method: clinical data and experimental testing.
BACKGROUND The proximal flow convergence method, a quantitative color Doppler flow technique, has been validated recently for calculating regurgitant flow and orifice area. We investigated the potential of the method as a tool to study different pathophysiological mechanisms of mitral valve incompetence by assessing the time course of regurgitant flow and orifice area and analyzed the implicati...
متن کاملWith Dilated Cardiomyopathy
The dynamics between mitral anulus motion, and, thus, motion of the base of the heart, and filling of the left atrium and ventricle were studied by Doppler echocardiography in 12 normal subjects and 28 patients with dilated cardiomyopathy. The normal motion of the mitral anulus is associated with two phases of inflow from the pulmonary veins. The first phase (J) of pulmonary venous inflow occur...
متن کاملCARDIOMYOPATHY Time variation of mitral regurgitant flow in patients with dilated cardiomyopathy
Angiographic results in patients with mitral regurgitation suggest that up to 50% of the regurgitant volume occurs during the preejection period. This contrasts markedly with the electromagnetic measurements of mitral regurgitant flow in anesthetized dogs, which suggest that only 5% of mitral regurgitant flow occurs during the preejection period. Therefore, we used two-dimensional and Doppler e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 74 4 شماره
صفحات -
تاریخ انتشار 1986