Triggered EMG Potentials in Determining Neuroanatomical Safe Zone for Transpsoas Lumbar Approach: Are They Reliable?

نویسندگان

  • Vishal Sarwahi
  • Abhijit Pawar
  • Etan Sugarman
  • Alan D Legatt
  • Aviva Dworkin
  • Beverly Thornhill
  • Yungtai Lo
  • Stephen F Wendolowski
  • Rachel C Gecelter
  • Marina Moguilevitch
چکیده

STUDY DESIGN In vivo analysis in swine model. OBJECTIVE The purpose of this study was to determine the accuracy of triggered EMG (t-EMG) and its reliability in lateral lumbar interbody fusions surgery. We also aim to document changes in psoas muscle produced during the approach. SUMMARY OF BACKGROUND DATA Lateral lumbar interbody fusions is preferred over direct anterior approach because of lower complications, blood loss, and shorter recovery time. Threshold-EMGs are utilized for real-time feedback about nerve location; however, neurological deficits are widely reported, and are unique to this approach. Multiple factors have been hypothesized including neuropraxia from retractors and compression from psoas hematoma/edema. The variable reports of neurological complication even with t-EMGs indicate the need to study them further. METHODS Eight swines underwent left-sided retroperitoneal approach. The nerve on the surface of the psoas was identified and threshold-EMGs were obtained utilizing a ball-tip, and needle probe. First EMG and threshold responses required to elicit 20-μV responses were recorded for 2 mm incremental distances up to 10 mm. In the second part, a K-wire was inserted into the mid-lumbar disc space, and a tubular retractor docked and dilated adequately. Postmortem CT scans were carried out to evaluate changes in psoas muscle. RESULTS A t-EMG stimulus threshold of <5 mA indicates a higher probability that the probe is close to or on the nerve, but this was not proportional to the distance suggesting limitations for nerve mapping. Negative predictive value of t-EMGs is 76.5% with the ball-tipped probe and 80% with the needle probe for t-EMG ≥10 mA and indicates that even with higher thresholds, the nerve may be much closer than anticipated. Postoperative hematoma was not seen on CT scans. CONCLUSION Threshold measurements are unreliable in estimating distance from the nerve in an individual subject and higher values do not always correspond to a 'safe zone." LEVEL OF EVIDENCE 5.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safe zone for retractor placement to the lumbar spine via the transpsoas approach.

PURPOSE To measure anatomic variations of the lumbar plexus within the psoas in relation to the L2/3, L3/4, and L4/5 disc spaces and to delineate a safe zone to avoid nerve injury during retractor placement via the transpsoas approach. METHODS Six male and 6 female cadavers (24 psoas/ lumbar plexuses) aged 35 to 74 years were dissected. The lumbar plexus was isolated bilaterally. The L2, L3, ...

متن کامل

Electromyographic monitoring and its anatomical implications in minimally invasive spine surgery.

STUDY DESIGN Literature review. OBJECTIVE The objective of this article is to examine current intraoperative electromyography (EMG) neurophysiologic monitoring methods and their application in minimally invasive techniques. We will also discuss the recent application of EMG and its anatomic implications to the minimally invasive lateral transpsoas approach to the spine. SUMMARY OF BACKGROUN...

متن کامل

Technical note: Resolution of spontaneous electromyographic discharge following disk-space distraction during lateral transpsoas interbody fusion

PURPOSE The lateral transpsoas interbody fusion (LTIF) is an increasingly popular minimally invasive technique for lumbar interbody fusion. Although a posterior approach to the lumbar spine has traditionally been favored for the treatment of canal stenosis and neural foraminal stenosis, a growing body of evidence suggests that indirect decompression of the spinal canal and neural foramen can be...

متن کامل

The relationship of intrapsoas nerves during a transpsoas approach to the lumbar spine: anatomic study.

STUDY DESIGN A cadaveric study. OBJECTIVE To define the relationship of the lumbar exiting nerve root and trunks within the psoas muscle with reference to the radiographic center of the intervertebral disc, the recommended disc access point for the minimally invasive lateral transpsoas approach. SUMMARY OF BACKGROUND DATA The transpsoas approach to the lumbar intervertebral body disc is a m...

متن کامل

Two-year clinical and radiographic success of minimally invasive lateral transpsoas approach for the treatment of degenerative lumbar conditions

BACKGROUND The lateral transpsoas approach to interbody fusion is a less disruptive but direct-visualization approach for anterior/anterolateral fusion of the thoracolumbar spine. Several reports have detailed the technique, the safety of the approach, and the short term clinical benefits. However, no published studies to date have reported the long term clinical and radiographic success of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 41 11  شماره 

صفحات  -

تاریخ انتشار 2016