Short-term exposure testing of six different passive samplers for the monitoring of hydrophobic contaminants in water.
نویسندگان
چکیده
Passive sampling devices are increasingly relied upon for monitoring non-polar organic contaminants in water. While many types of devices are available they have seldom been evaluated alongside each other. We tested six passive sampling devices namely: Chemcatcher, two modified versions of the membrane enclosed sorptive coating (MESCO I (m) and MESCO II), silicone rod and strip and semipermeable membrane device (SPMD). Samplers spiked with a range of performance reference compounds (PRCs) were exposed (5 days) in a continuous flow-through tank using Meuse river water fortified with fluctuating concentrations (20-700 ng L(-1)) of polycyclic aromatic hydrocarbons, polychlorinated biphenyls, hexachlorobenzene and p,p'-DDE. Dissipation rates of PRCs appeared to provide reliable information on exchange kinetics even under these short-term exposure conditions. They accounted for differences between masses of contaminants accumulated by replicate samplers, indicating that the variability between replicates was in part due to differences in water turbulences and hence boundary layer thickness. In this system, resistances in the membrane and boundary layers are likely to be in the same order of magnitude for PRCs. Sampler performance was evaluated by comparing masses accumulated in the devices only for analytes for which uptake was linear (integrative) and limited by transport across the boundary layer. Consistent data were obtained across the range of samplers despite their different configurations, and the analysis being conducted in three separate laboratories. The pattern in analyte masses accumulated by Chemcatcher and MESCO II data could be explained by the extraction and analysis being conducted only on the receiving phase of the samplers and a significant impact of the lag-phase prior to obtaining a steady flux of contaminants across the polyethylene membranes.
منابع مشابه
Performance of semipermeable membrane devices for sampling of organic contaminants in groundwater.
Lipid-filled semipermeable membrane devices (SPMDs) are receiving increasing attention as passive, in situ samplers for the assessment of environmental pollutant exposure. Although SPMDs have been successfully used in a variety of field studies in surface waters, only a few studies have addressed their characteristics as groundwater samplers. In this study, the performance of the SPMDs for moni...
متن کاملApplication of passive sampling for measuring dissolved concentrations of organic contaminants in the water column at three marine superfund sites.
Currently, there is an effort under way to encourage remedial project managers at contaminated sites to use passive sampling to collect freely dissolved concentrations (Cfree ) of hydrophobic organic contaminants to improve site assessments. The objective of the present study was to evaluate the use of passive sampling for measuring water column Cfree for several hydrophobic organic contaminant...
متن کاملGuidelines for passive sampling of hydrophobic contaminants in water using silicone rubber samplers
متن کامل
Improving Toxicity Assessment of Pesticide Mixtures: The Use of Polar Passive Sampling Devices Extracts in Microalgae Toxicity Tests
Complexity of contaminants exposure needs to be taking in account for an appropriate evaluation of risks related to mixtures of pesticides released in the ecosystems. Toxicity assessment of such mixtures can be made through a variety of toxicity tests reflecting different level of biological complexity. This paper reviews the recent developments of passive sampling techniques for polar compound...
متن کاملUsing performance reference compound-corrected polyethylene passive samplers and caged bivalves to measure hydrophobic contaminants of concern in urban coastal seawaters.
Low-density polyethylene (PE) passive samplers containing performance reference compounds (PRCs) were deployed at multiple depths in two urban coastal marine locations to estimate dissolved concentrations of hydrophobic organic contaminants (HOCs), including dichlorodiphenyltrichloroethane (DDT) and its metabolites, polychlorinated biphenyl (PCB) congeners, and polybrominated flame retardants. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of environmental monitoring : JEM
دوره 12 3 شماره
صفحات -
تاریخ انتشار 2010