Marginal bone and soft tissue behavior following platform switching abutment connection/disconnection--a dog model study.
نویسندگان
چکیده
OBJECTIVE The effect on the marginal peri-implant tissues following repeated platform switching abutment removal and subsequent reconnection was studied. MATERIAL AND METHODS Six adult female Beagle dogs were selected, and Pm3 and Pm4 teeth, both left and right sides, were extracted and the sites healed for 3 months. At this time, 24 bone level (BL) (Straumann, Basel, Switzerland) Ø 3.3/8 mm implants were placed, 2 in each side on Pm3 and Pm4 regions. In one side (control group), 12 bone level conical Ø 3.6 mm healing abutments and, on the other side (test group), 12 Narrow CrossFit (NC) multibase abutments (Straumann) , Basel, Switzerland) were connected at time of implant surgery. On test group, all prosthetic procedures were carried out direct to multibase abutment without disconnecting it, where in the control group, the multibase abutment was connected/disconnected five times (at 6/8/10/12/14 weeks) during prosthetic procedures. Twelve fixed metal bridges were delivered 14 weeks after implant placement. A cleaning/control appointment was scheduled 6 months after implant placement. The animals were sacrificed at 9 months of the study. Clinical parameters and peri-apical x-rays were registered in every visit. Histomorphometric analysis was carried out for the 24 implants. The distance from multibase abutment shoulder to the first bone implant contact (S-BIC) was defined as the primary histomorphometric parameter. RESULTS Wilcoxon comparison paired test (n = 6) found no statistically significant differences (buccal P = 0.917; Lingual P = 0.463) between test and control groups both lingually and buccally for S-BIC distance. Only Pm3 buccal aBE-BC (distance from the apical end of the barrier epithelium to the first bone implant contact) (P = 0.046) parameter presented statistically significant differences between test and control groups. Control group presented 0.57 mm more recession than test group, being this difference statistically significant between the two groups (P < 0.001). CONCLUSION It can be conclude, within the limits of this animal study, that the connection/disconnection of platform switching abutments during prosthetic phase of implant treatment does not induce bone marginal absorption. Furthermore, it may present a negative influence in the buccal connective tissue attachment that becomes shorter anyway preventing marginal hard tissue resorption, especially in thin biotypes.
منابع مشابه
The impact of the type and configuration of abutments and their (repeated) removal on the attachment level and marginal bone.
PURPOSE The quality and stability of the soft tissue-implant interface is most likely of paramount importance for the preservation of marginal bone and for the long-term prognosis of oral implants. The aim of the present review was to screen existing data in the literature concerning the influence of transmucosal components' composition, type, design and disconnection on peri-implant tissues. ...
متن کاملRadiographic evaluation of conical tapered platform‐switched implants in the posterior mandible: 1‐year results of a two‐center prospective study
OBJECTIVE Long-term success of dental implants depends on healthy peri-implant soft tissues and adequate bone levels. This prospective study aims to assess bone level changes around implants with internal conical connection and platform-switching abutments in the posterior mandible. MATERIAL AND METHODS Adult patients missing at least two teeth in the posterior mandible and with a natural too...
متن کاملPlatform switching for marginal bone preservation around dental implants: a systematic review and meta-analysis.
BACKGROUND Platform switching for maintaining peri-implant bone levels has gained popularity among implant manufacturers over the last few years. However, the assumption that the inward shifting of the implant-abutment junction may preserve crestal bone was primarily based on serendipitous finding rather than scientific evidence. The objectives of the present study were to systematically review...
متن کاملBansal P , Bhatia A , Mehta A . Platform Switching - Preserving the Crestal Bone
relevant studies was conducted using electronic The long-term success of an implant depends upon search of the Medline/ Pub Med, Google scholar and integration between implants, hard and soft tissues. related articles. The search words include platform Marginal bone loss around implant may pose a threat switching, biologic width, peri-implant soft tissue, to a long-term survival. Concept of pla...
متن کاملFactors influencing the preservation of the periimplant marginal bone.
Esthetic outcomes cannot be attributed to a single parameter. Rather, as this article shows, they are the result of a number of important factors, especially in the esthetic zone. An understanding of the meaning of biologic width, of the integration of the platform-switching concept into implant treatment facilitates the preservation of a stable marginal bone level around the implant neck. This...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical oral implants research
دوره 26 9 شماره
صفحات -
تاریخ انتشار 2015