Image registration required for magnetic resonance imaging experiments of accommodation.
نویسندگان
چکیده
Using 7 Tesla magnetic resonance imaging (MRI), Richdale et al. measured the change in lens and ciliary muscle ring dimensions of the occluded right eyes of 26 emmetropic subjects (30–50 years of age) while their left eyes changed fixation on a Maltese cross placed at different distances to stimulate from 0 to 6 diopters of accommodation. The MRI scans were repeated at least eight times for each accommodative demand over a time period of 10 minutes. A masked examiner identified the central slice of each scan and measured the equatorial lens diameter, central lens thickness, and ciliary muscle ring diameters. The authors do not specify how the masked examiner determined the central slice of each scan, and the reproducibility of the measurements (mean, SD, and range) are not given for the eight MRI scans of each subject at each accommodative demand. In addition, the authors make statements of correlations, but do not supply the coefficients of determination, r, so the reader can assess the strength of the authors’ conclusions. Examination of the authors’ Figure 7 demonstrates that there was an increase in lens equatorial diameter in response to the 2 diopter (D) and 4 D accommodative demands in eight subjects, Figure A, B. According to the generally accepted Helmholtz’s theory of accommodation, the lens equatorial diameter (LED) must always decrease during accommodation greater than zero D. The finding that 8 of 26 subjects, 31% (5 were <40 years of age), had an increase in LED brings into question the reliability of the authors’ measurements and/or the Helmholtz theory of accommodation. One possibility to account for the authors’ findings is that they compared images taken from different planes due to convergence and cyclotorsion of the nonfixating eye. For example, since the mean accommodative convergence and cyclotorsion for the subjects’ age is expected to be approximately 128 and 1.68, respectively, for 4 D of accommodation and the mean baseline LED of the subjects was 9.42 mm, the observed approximate mean 0.2 mm decrease in LED for the 4 D demand, Figure B, may have resulted from an offaxis measurement: 9.42 mm 9.42 mm cos(128) cos(1.68) 1⁄4 0.2 mm. Unfortunately, the reader is unable to independently assess whether the compared images were obtained from identical planes, since the authors do not supply MRI images of the unaccommodative and maximally accommodated eye of a subject. In addition, it is not clear why the authors omitted the four subjects in the 40to 45-year-old age group from the scattergrams of their Figure 7. In summary, nonrandom accommodative eye movements may have caused a systematic error in the authors’ study. Similar to the other studies referenced by the authors, the authors’ study is flawed because multiple unchanging positional references were not included in their analysis to permit proper image registration. This methodological omission and the lack of proper controls make the authors’ measurements of the dimensional and directional changes of the lens and ciliary muscle during accommodation unreliable.
منابع مشابه
New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor
Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...
متن کاملPseudo-CT Generation from Magnetic Resonance Imaging by fuzzy look up table algorithm
Introduction: Despite growing interest in the use of magnetic resonance imaging (MRI) in the external radiotherapy design process (RT), Computer Tomography (CT) remains a gold standard and is regarded as a basic imaging modality in radiotherapy. MRI shows the high contrast in soft tissues without any radiation exposure to patients. As a result, MRI is used in functional tissue ...
متن کاملGenerating Synthetic Computed Tomography and Synthetic Magnetic Resonance (sMR: sT1w/sT2w) Images of the Brain Using Atlas-Based Method
Introduction: Nowadays, magnetic resonance imaging (MRI) in combination with computed-tomography (CT) is increasingly being used in radiation therapy planning. MR and CT images are applied to determine the target volume and calculate dose distribution, respectively. Since the use of these two imaging modalities causes registration uncertainty and increases department w...
متن کاملNon-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)
Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...
متن کاملA Bayesian approach for image denoising in MRI
Magnetic Resonance Imaging (MRI) is a notable medical imaging technique that is based on Nuclear Magnetic Resonance (NMR). MRI is a safe imaging method with high contrast between soft tissues, which made it the most popular imaging technique in clinical applications. MR Imagechr('39')s visual quality plays a vital role in medical diagnostics that can be severely corrupted by existing noise duri...
متن کاملA New Potential Contrast Agent for Magnetic Resonance Imaging: Iron Oxide-4A Nanocomposite
Background: Magnetic resonance imaging (MRI) contrast agents have an important role to differentiate healthy and diseased tissues. Access and design new contrast agents for the optimal use of MRI are necessary. This study aims to evaluate iron oxide–4A nanocomposite ability to act as a magnetic resonance imaging contrast agent.Materials and Methods: Iron oxide–4A nanocomposite (F4A) was syn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 54 3 شماره
صفحات -
تاریخ انتشار 2013