Antibody Colocalization Microarray: A Scalable Technology for Multiplex Protein Analysis in Complex Samples*
نویسندگان
چکیده
DNA microarrays were rapidly scaled up from 256 to 6.5 million targets, and although antibody microarrays were proposed earlier, sensitive multiplex sandwich assays have only been scaled up to a few tens of targets. Cross-reactivity, arising because detection antibodies are mixed, is a known weakness of multiplex sandwich assays that is mitigated by lengthy optimization. Here, we introduce (1) vulnerability as a metric for assays. The vulnerability of multiplex sandwich assays to cross-reactivity increases quadratically with the number of targets, and together with experimental results, substantiates that scaling up of multiplex sandwich assays is unfeasible. We propose (2) a novel concept for multiplexing without mixing named antibody colocalization microarray (ACM). In ACMs, both capture and detection antibodies are physically colocalized by spotting to the same two-dimensional coordinate. Following spotting of the capture antibodies, the chip is removed from the arrayer, incubated with the sample, placed back onto the arrayer and then spotted with the detection antibodies. ACMs with up to 50 targets were produced, along with a binding curve for each protein. The ACM was validated by comparing it to ELISA and to a small-scale, conventional multiplex sandwich assay (MSA). Using ACMs, proteins in the serum of breast cancer patients and healthy controls were quantified, and six candidate biomarkers identified. Our results indicate that ACMs are sensitive, robust, and scalable.
منابع مشابه
Multiplex approaches in protein microarray technology.
The success of genome sequencing projects has provided the basis for systematic analysis of protein function and has led to a shift from the description of single molecules to the characterization of complex samples. Such a task would not be possible without the provision of appropriate high-throughput technologies, such as protein microarray technology. In addition, the increasing number of sa...
متن کاملSensitive single-molecule protein quantification and protein complex detection in a microarray format.
Single-molecule protein analysis provides sensitive protein quantitation with a digital read-out and is promising for studying biological systems and detecting biomarkers clinically. However, current single-molecule platforms rely on the quantification of one protein at a time. Conventional antibody microarrays are scalable to detect many proteins simultaneously, but they rely on less sensitive...
متن کاملDDT April 1 2005.qxd
503 www.drugdiscoverytoday.com The basic concept of microarray technology (see Glossary) was initiated by the ambient analyte model of Ekins and colleagues [1–3], which states that ‘microspot’ assays that rely on the immobilisation of interacting elements on a few square microns should, in principle, be capable of detecting analytes with a higher sensitivity than conventional macroscopic immuno...
متن کاملA Multiplex Label-Free Approach to Avian Influenza Surveillance and Serology
Influenza serology has traditionally relied on techniques such as hemagglutination inhibition, microneutralization, and ELISA. These assays are complex, challenging to implement in a format allowing detection of several types of antibody-analyte interactions at once (multiplex), and troublesome to implement in the field. As an alternative, we have developed a hemagglutinin microarray on the Arr...
متن کاملجداسازی و شناسایی آنتیژن RhD از غشای گلبول قرمز به روش رسوب ایمنی
Background and Objective: Rh (Rhesus) is a highly complex blood group system in man which plays an important role in transfusion medicine. The aim of this study was the isolation of RhD protein from the membrane of RBCs. Materials and Methods: In this experimental study immunoprecipitation method with human anti-RhD polyclonal antibody was utilized for the isolation of RhD antigen from Rh+ huma...
متن کامل