A 3D point-kernel multiple scatter model for parallel-beam SPECT based on a gamma-ray buildup factor.

نویسندگان

  • Predrag Marinkovic
  • Radovan Ilic
  • Rajko Spaic
چکیده

A three-dimensional (3D) point-kernel multiple scatter model for point spread function (PSF) determination in parallel-beam single-photon emission computed tomography (SPECT), based on a dose gamma-ray buildup factor, is proposed. This model embraces nonuniform attenuation in a voxelized object of imaging (patient body) and multiple scattering that is treated as in the point-kernel integration gamma-ray shielding problems. First-order Compton scattering is done by means of the Klein-Nishina formula, but the multiple scattering is accounted for by making use of a dose buildup factor. An asset of the present model is the possibility of generating a complete two-dimensional (2D) PSF that can be used for 3D SPECT reconstruction by means of iterative algorithms. The proposed model is convenient in those situations where more exact techniques are not economical. For the proposed model's testing purpose calculations (for the point source in a nonuniform scattering object for parallel beam collimator geometry), the multiple-order scatter PSF generated by means of the proposed model matched well with those using Monte Carlo (MC) simulations. Discrepancies are observed only at the exponential tails mostly due to the high statistic uncertainty of MC simulations in this area, but not because of the inappropriateness of the model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A STUDY OF GAMMA RAY EXPOSURE BUILDUP FACTORS IN STRATIFIED SHIELDS FOR POINT ISOTROPIC SOURCES, INCLUDING THE EFFECTS OF INCOHERENT AND COHERENT SCATTERING

The effects of including incoherent (bound-electron) and coherent (Rayleigh) scattering in exposure buildup factor calculations for point isotropic gamma ray sources, penetrating a two-layer water-lead shield have been investigated in the gamma ray energy (E?) range of 40 keV to 3 MeV. Incoherent scattering decreases the values of these factors in both layers up to E? ~ 200 keV and the effect i...

متن کامل

Analytical Solution to 3D SPECT Reconstruction with Non-uniform Attenuation, Scatter, and Spatially-variant Resolution Variation for Variable Focal-length Fan-beam Collimators

In the past decades, analytical (non-iterative) methods have been extensively investigated and developed for the reconstruction of three-dimensional (3D) single-photon emission computed tomography (SPECT). However, it becomes possible only recently when the exact analytic non-uniform attenuation reconstruction algorithm was derived. Based on the explicit inversion formula for the attenuated Rad...

متن کامل

Evaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT Images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators

Objective(s): The purpose of this study was to examine the optimal reconstruction parameters for brain dopamine transporter SPECT images obtained with a fan beam collimator and compare the results with those obtained by using parallel-hole collimators.Methods: Data acquisition was performed using two SPECT/CT devices, namely a Symbia T6 and an Infinia Hawkeye 4 (device A and B) equipped with fa...

متن کامل

A Generalized Model for 3D Compton Scatter in Single Photon Emission Computed Tomography Using Slice-by-Slice Blurring and Scatter Projection Rebinning

The modeling of 3D Compton scatter in SPECT is complicated by the use of a variety of collimator geometry. To date, effective and efficient modeling of 3D Compton scatter in parallel-beam SPECT has been made possible by Frey and Tsui [1], Zeng et al [2], and Bai et al [3]. For fan-beam and cone-beam SPECT, the model in [3] can effectively model first order 3D Compton scatter. But for varying-fo...

متن کامل

Study on effect of detector type in estimating buildup factor of gamma-rays by monte carlo simulation based on variance reduction

This paper presents the study on the effect of detector type in estimating gamma rays buildup factor. In this regard, the flux buildup factors of gamma rays emitted by an isotropic point 60Co source in mean energy 1.253 MeV was evaluated after passing through the Pb, W, Zn, and Ti sample in thickness of 1-5 cm by MCNPX. Four common detector types in simulation of measurement was defined to esti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 52 19  شماره 

صفحات  -

تاریخ انتشار 2007