Rebuttal from Daniel Beard and Eric Feigl.
نویسندگان
چکیده
Dr. Andrew’s proposal (Andrew, 2013) to rename Guyton’s venous return curve the ‘venous pressure curve’ seems unlikely to overcome the decades of misinterpretation and confusion that the Guytonmodel of the systemic circulation has engendered. In Guyton’s experiments venous return curves were produced with a pump connected from the right atrium to the pulmonary artery in an anaesthetized, open chest, horizontal, acute preparation. Paired data points of flow and right atrial pressure were obtained. Guyton fitted the data pairs with a four-parameter model, consisting of arterial and venous resistances and capacitances. The model fitted the data at
منابع مشابه
Myocardial oxygenation and adenosine release in isolated guinea pig hearts during changes in contractility.
Previous work from this laboratory using near-infrared optical spectroscopy of myoglobin has shown that approximately 20% of the myocardium is hypoxic in buffer-perfused hearts that are perfused with fully oxygenated buffer at 37 degrees C. The present study was undertaken to determine cardiac myoglobin saturation in buffer-perfused hearts when cardiac contractility was increased with epinephri...
متن کاملComparison of buffer and red blood cell perfusion of guinea pig heart oxygenation.
Myocardial mean myoglobin oxygen saturation was determined spectroscopically from isolated guinea pig hearts perfused with red blood cells during increasing hypoxia. These experiments were undertaken to compare intracellular myoglobin oxygen saturation in isolated hearts perfused with a modest concentration of red blood cells (5% hematocrit) with intracellular myoglobin saturation previously re...
متن کاملUnderstanding Guyton's venous return curves.
Based on observations that as cardiac output (as determined by an artificial pump) was experimentally increased the right atrial pressure decreased, Arthur Guyton and coworkers proposed an interpretation that right atrial pressure represents a back pressure restricting venous return (equal to cardiac output in steady state). The idea that right atrial pressure is a back pressure limiting cardia...
متن کاملOpen-loop (feed-forward) and feedback control of coronary blood flow during exercise, cardiac pacing, and pressure changes.
A control system model was developed to analyze data on in vivo coronary blood flow regulation and to probe how different mechanisms work together to control coronary flow from rest to exercise, and under a variety of experimental conditions, including cardiac pacing and with changes in coronary arterial pressure (autoregulation). In the model coronary flow is determined by the combined action ...
متن کاملMyocardial oxygenation in isolated hearts predicted by an anatomically realistic microvascular transport model.
An anatomically realistic model for oxygen transport in cardiac tissue is introduced for analyzing data measured from isolated perfused guinea pig hearts. The model is constructed to match the microvascular anatomy of cardiac tissue based on available morphometric data. Transport in the three-dimensional system (divided into distinct microvascular, interstitial, and parenchymal spaces) is simul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of physiology
دوره 591 23 شماره
صفحات -
تاریخ انتشار 2013