Indications, methodology, and interpretation of combined esophageal impedance-pH monitoring in children: ESPGHAN EURO-PIG standard protocol.

نویسندگان

  • Tobias G Wenzl
  • Marc A Benninga
  • Clara M Loots
  • Silvia Salvatore
  • Yvan Vandenplas
چکیده

AIM The aim of the study was to provide an updated position statement from the ESPGHAN European Pediatric Impedance Working Group on different technical aspects such as indications, methodology, and interpretation of multichannel intraluminal impedance-pH monitoring (MII-pH). METHODS Evidence was used where available, but the article is based mainly on expert opinion and consensus. RESULTS MII-pH provides more information than simple pH monitoring because reflux detection is not limited to acid reflux. Different companies provide commercialized MII-pH recording systems, making the method widely available and useable in daily clinical practice; however, the technique still has limitations: high cost, limited additional value regarding therapeutic implications, and lack of evidence-based parameters for the assessment of gastroesophageal reflux and symptom association in children. CONCLUSIONS MII-pH recording is a promising procedure needing further validation and development to increase its additional benefit over conventional investigation techniques. The added value of the technique regards mainly clinical circumstances in which nonacid or weakly acid reflux may be relevant such as persisting symptoms during antireflux treatment with proton pump inhibitors and feeding-related reflux; and assessing specific discontinuous symptoms thought to be associated with gastroesophageal reflux; and research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Principles of Combined Esophageal Impedance-ph Monitoring in Children: Indications, Benefits and Limitations

The standard test for suspected gastroesophageal refl ux is pH monitoring. However, the majority of gastroesophageal refl ux episodes in infants and children are nonacidic (pH > 4) and extraesophageal symptoms apparently can be caused by both acidic (pH < 4) and nonacidic refl ux. In order to overcome these aspects, a new technique has been developed and placed under scrutiny in the past twenty...

متن کامل

Esophageal pH and Combined Impedance-pH Monitoring in Children

Esophageal pH monitoring is considered the gold standard for the diagnosis of gastroesophageal reflux disease because of the normal ranges across the pediatric age range. However, this method can only detect acid reflux. Multichannel intraluminal impedance-pH (MII-pH) monitoring has recently been used for the detection of bolus reflux in infants and children. This method allows for the detectio...

متن کامل

Use of Esophageal Impedance beyond Diagnosis of GERD

Combined multichannel intraesophageal impedance-pH (MII-pH) monitoring is currently the the gold standard method to diagnosis of gastroesophageal reflux disease (GERD). A standard MII-pH catheter has six pairs of impedance electrodes. Multiple impedance-measuring within the esophagus allows determination of direction of bolus movement within the esophagus. So that MII is used as a good esophage...

متن کامل

How to Interpret Esophageal Impedance pH Monitoring

Esophageal impedance pH monitoring provides quantitative data on esophageal acid exposure and has the ability to correlate the symptoms with acid exposure events. The nomenclature for the reflux patterns detected in impedance pH monitoring as well as the normal values have been determined. Data interpretation is similar to 24-hour pH monitoring, ie, searching for an increase in the number of re...

متن کامل

Diagnostic difficulties during combined multichannel intraluminal impedance and pH monitoring in patients with esophagitis or Barrett's esophagus.

Gastroesophageal reflux disease (GERD) is one of the most common esophageal diseases in developed countries. It is widely believed that GERD symptoms are caused by acid refluxate within the esophagus, so ambulatory 24 hour pH-monitoring became the gold standard in detecting gastroesophageal reflux. Traditional ambulatory pH monitoring is unable to detect a gastroesophageal reflux with pH >4. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pediatric gastroenterology and nutrition

دوره 55 2  شماره 

صفحات  -

تاریخ انتشار 2012