New Assessment Model of Pulse Depth Based on Sensor Displacement in Pulse Diagnostic Devices

نویسندگان

  • Jang-Han Bae
  • Young Ju Jeon
  • Jong Yeol Kim
  • Jaeuk U. Kim
چکیده

An accurate assessment of the pulse depth in pulse diagnosis is vital to determine the floating and sunken pulse qualities (PQs), which are two of the four most basic PQs. In this work, we proposed a novel model of assessing the pulse depth based on sensor displacement (SD) normal to the skin surface and compared this model with two previous models which assessed the pulse depth using contact pressure (CP). In contrast to conventional stepwise CP variation tonometry, we applied a continuously evolving tonometric mechanism at a constant velocity and defined the pulse depth index as the optimal SD where the largest pulse amplitude was observed. By calculating the pulse depth index for 18 volunteers, we showed that the pulse was deepest at Cheok (significance level: P < 0.01), while no significant difference was found between Chon and Gwan. In contrast, the two CP-based models estimated that the pulse was shallowest at Gwan (P < 0.05). For the repeated measures, the new SD-based model showed a smaller coefficient of variation (CV ≈ 7.6%) than the two CP-based models (CV ≈ 13.5% and 12.3%, resp.). The SD-based pulse depth assessment is not sensitive to the complex geometry around the palpation locations and temperature variation of contact sensors, which allows cost-effective sensor technology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A WAVELET-BASED PROCEDURE FOR MINING OF PULSE-LIKE GROUND MOTIONS FEATURES ON RESPONSE SPECTRA

The main objective of this paper is to present a wavelet-based procedure to characterize principle features of a special class of motions called pulse-like ground motions. Initially, continues wavelet transform (CWT) which has been known as a powerful technique both in earthquake engineering and seismology field is applied easily in automated detecting of strong pulse of earthquakes. In this pr...

متن کامل

Optical pulse compression based on nonlinear silicon waveguides and chirped Bragg gratings

Due to the growing demand for higher bandwidth, employing optical devices instead of electronic devices in data transmission systems has attracted much attention in recent years. Optical switches, modulators and wavelength converters are a few examples of the required optical devices. CMOS compatible fabrication of these devices, leads to much more growing of this technology. Optical pulse comp...

متن کامل

Alumina nanoparticles modified carbon paste electrode as a new voltammetric sensor for determination of dopamine

The present study examines a new dopamine sensor based on Alumina nanoparticles modified carbon paste electrode (Al2O3NPsCPE). Moreover, the present study focuses on the electrochemical act of the Al2O3NPsCPE for the detection of dopamine by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). There is also a focus on the specification of the prepared modified electrode by electroc...

متن کامل

The Assessment of Second Pulse Effects on the Microstructure and Fracture Behavior of the Resistance Spot Welding in Advanced Ultrahigh-Strength Steel TRIP1100

In this study, the effects of the second pulse resistance spot welding on the microstructure and mechanical properties of TRIP1100 steel were evaluated. The thermal process after welding was designed to improve metallurgical properties with pulse currents of 6kA, 9kA and 12kA after initial welding with 10kA current. The effect of the second pulse on mechanical and microstructural properties was...

متن کامل

Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp

Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013