Test of dynamic closed-loop baroreflex and autoregulatory control of total peripheral resistance in intact and conscious sheep.
نویسندگان
چکیده
This is the first study able to examine and delineate the actual actions of the physiological mechanisms responsible for the dynamic couplings between cardiac output (CO), arterial pressure (Pa), right atrial pressure (PRA), and total peripheral resistance (TPR) in an individual subject without altering the underlying regulatory mechanisms. Eight conscious male sheep were used, where both types of baroreceptors were independently exposed to simultaneous beat-to-beat pressure perturbations under intact closed-loop conditions while CO, Pa, PRA, and TPR were measured. We applied the cardiovascular system identification method proposed in a companion paper (4) to quantitatively characterize the dynamic closed-loop transfer relations CO-->Pa, PRA-->Pa, Pa-->TPR, and PRA-->TPR from the measured signals. To validate the dynamic properties of the estimated transfer relations, the essential parts of the linear dynamics of the model were independently and comprehensively evaluated via error model cross-validation, and the overall model's steady-state behavior was compared with a separate random effects regression approach. In addition to numerous physiological findings, we found that the cardiovascular system identification results were exceptionally consistent with the analytically derived solutions previously discussed in Ref. 4. In conclusion, this study presents the first time validation of a cardiovascular system identification method by means of experimentally acquired animal data in the intact and conscious animal and offers a set of powerful quantitative tools essential to advancing our knowledge of cardiovascular regulatory physiology.
منابع مشابه
Theoretical considerations in the dynamic closed-loop baroreflex and autoregulatory control of total peripheral resistance.
The most important goal of this study is to enhance our understanding of the crucial functional relationships that determine the behavior of the systemic circulation and its underlying physiological regulatory mechanisms with minimal modeling. To the present day, much has been said about the indirect hydraulic effects of right atrial pressure (PRA) via cardiac output (CO) on arterial pressure (...
متن کاملDynamic Load Carrying Capacity of Mobile-Base Flexible-Link Manipulators: Feedback Linearization Control Approach
This paper focuses on the effects of closed- control on the calculation of the dynamic load carrying capacity (DLCC) for mobile-base flexible-link manipulators. In previously proposed methods in the literature of DLCC calculation in flexible robots, an open-loop control scheme is assumed, whereas in reality, robot control is achieved via closed loop approaches which could render the calculated ...
متن کاملEstimation of arterial and cardiopulmonary total peripheral resistance baroreflex gain values: validation by chronic arterial baroreceptor denervation.
Feedback control of total peripheral resistance (TPR) by the arterial and cardiopulmonary baroreflex systems is an important mechanism for short-term blood pressure regulation. Existing methods for measuring this TPR baroreflex mechanism typically aim to quantify only the gain value of one baroreflex system as it operates in open-loop conditions. As a result, the normal, integrated functioning ...
متن کاملManaging Environmentally Conscious in Designing Closed-loop Supply Chain for the Paper Industry
High amounts of waste paper are disposed of every year in Iran posing the health hazard and environmental damages instead of being recovered. Collection, recovery and proper disposal of waste paper without damaging the environment need to design an efficient closed-loop supply chain network. The main objective of this paper is introducing a bi-objective, multi-echelon, multi-product and single-...
متن کاملSystems physiology of the baroreflex during orthostatic stress: from animals to humans
The baroreflex is a key mechanism involved in the control of arterial pressure (AP) during orthostasis in humans. However, the baroreflex is a closed-loop feedback system, from baroreceptor pressure input to systemic AP, and therefore requires open-loop experiments to identify its system characteristics. The requirement limits our ability to identify baroreflex system characteristics in humans....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 287 5 شماره
صفحات -
تاریخ انتشار 2004