Thermoeconomic Lifecycle Energy Recovery System Optimization for Central Air-Conditioning System Using Evolutionary Technique
نویسنده
چکیده
Energy efficient systems are the most desirable systems. Due to huge rise in energy prices and lack of availability of energy, the effective use of energy has become the need of time. Energy recovery both in heating systems as well as in air-conditioning systems saves a lot of energy. In this paper energy recovery system has been designed and optimized for central air-conditioning systems for various ranges. Cost function includes capital cost along with pumping and exergy destruction cost. This shows that installation of energy recovery system with a central air-conditioning has a significant amount of saved energy and payback period is within a year. PFHE (Plate Fin Heat Exchanger) is designed and optimized using evolutionary optimization. In order to verify the capabilities of the proposed method, a case study is also presented showing that significant amount of energy is recovered at a reasonable payback period. Sensitivity analysis is also done with the energy prices.
منابع مشابه
Fully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology
The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...
متن کاملDesign and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study
In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...
متن کاملThermodynamic and Thermoeconomic Optimization of an Absorption Refrigeration System integrated with Refinery Crude Oil Furnace
In the present study, exhaust gases from Tehran refinery crude oil furnace are used in a Heat Recovery Steam Generator (HRSG)for generating steam. Then, the steam is directed to a double effect absorption refrigeration cycle to produce cooling. To meet the object, mass and energy balance equations of the coupling is carried out for both the HRSG and the absorption chiller and unknown thermodyna...
متن کاملExergy and Thermoeconomic Analysis for an Underground Train Station Air-Conditioning Cooling System
The necessity of air-conditioning causes the enormous energy use of underground train stations. Exergy and thermoeconomic analysis is applied to the annual operation of the air-conditioning system of a large underground train station in Taiwan. The current installation and the monitored data are taken to be the base case, which is then compared to three different optimized designs. The total re...
متن کاملMethods for Analyzing the Energy Efficiencyand Cost Effectiveness of Evaporative Cooling Air Conditioning
Air conditioning systems of houses consume large quantity of electricity. To reducing energy consumption for air conditioning purposes it is becoming attractive the use of evaporative cooling air conditioning which is less energy consuming compared to air chillers. But, it is obvious that higher energy efficiency of evaporative cooling is not enough to judge whether evaporative cooling economic...
متن کامل