Response tests of a LaCl(3):Ce scintillation detector with low energy prompt gamma rays from boron and cadmium.

نویسندگان

  • A A Naqvi
  • M S Al-Anezi
  • Zameer Kalakada
  • Faris A Al Matouq
  • M Maslehuddin
  • M A Gondal
  • A A Isab
  • Khateeb-ur-Rehman
  • M Dastageer
چکیده

The yield of 478 and 558 keV gamma-rays have been measured from water samples containing 0.031-0.500 wt. % boron and 0.0625-0.500 wt. % cadmium, respectively, using a cylindrical 76 mm × 76 mm (height × diameter) LaCl(3):Ce detector. Inspite of interferences between detector-associated and the sample-associated prompt gamma rays, the LaCl(3):Ce detector has excellent resolution for the low energy prompt gamma-rays. An excellent agreement has been observed between the experimental and calculated yield of boron and cadmium prompt gamma ray from water samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of Am-Be neutron source based PGNAA setup using aqueous solutions of Chlorine and Boron

Background: A 5 Ci 241Am-Be radio isotopic neutron source-based prompt gamma neutron activation analysis (PGNAA) setup was designed for estimation of minimum detectable concentration (MDC) of elements in aqueous solutions. Materials and Methods: Performance variables related to PGNAA setup (source to sample distance, sample to detector distance and volume of water) were optimized experimentally...

متن کامل

Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

متن کامل

A Monte Carlo study of SPECT in boron neutron capture therapy for a heterogeneous human phantom

Background: Boron neutron capture therapy (BNCT) is a binary radiotherapy combining biochemical targeting with neutron irradiation. However, monitoring the boron distribution is a fundamental problem in BNCT. Prompt gamma rays emitted by boron capture reaction can be used to address the issue. Materials and Methods: The general-purpose Monte Carlo toolkits Geant4 and MCNP were used for the simu...

متن کامل

شبیه‌سازی تابع پاسخ سوسوزن‌های آلی به تابش گاما و نوترون با استفاده از کدهای مونت کارلوی FLUKA،MCNPX و SCINFUL

In organic scintillators, the energy distribution of gamma rays and neutrons is indirectly measured by the pulse height distribution of light output produced through gamma ray and neutron reactions in the detectors. Accurate estimate of the interaction of gamma and neutrons in the detector and produce charged secondary particles and subsequent scintillation light produced in the calculation of ...

متن کامل

Nonproportional response of LaBr3:Ce and LaCl3:Ce scintillators to synchrotron x-ray irradiation.

The nonproportional scintillation response of LaBr(3) doped with 5% Ce(3+) and of LaCl(3) doped with 10% Ce(3+) was measured using highly monochromatic synchrotron irradiation. To estimate the photon response, pulse height spectra at many finely spaced energy values between 9 and 100 keV were measured. The experiment was carried out at the X-1 beamline at the Hamburger Synhrotronstrahlungslabor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

دوره 70 5  شماره 

صفحات  -

تاریخ انتشار 2012