Elution of residual monomers from dental composite materials.

نویسندگان

  • E B Tuna
  • O Aktoren
  • Y Oshida
  • K Gencay
چکیده

AIM This study was designed to determine the type and amount of the monomers leached from the different particle sizes of the composite materials. MATERIALS AND METHODS Three different disk sizes (2, 4, 6 mm) prepared for each material group (Filtek Flow, Filtek A110, Filtek P60 and Filtek Supreme) were polymerised by LED and halogen light; the specimens were then placed in artificial saliva. The monomer release in 30 min and 24 hrs from the specimens was analyzed in HPLC calibrated for the monomer extracts before. RESULTS TEGDMA release was detected in all material groups after 30 min and after 24 hrs. BisGMA and BisEMA were not determined in any groups and UDMA was detected only in Filtek Supreme. Significant differences in release of TEGDMA and UDMA were obtained between the different sizes of discs. Significantly high amount of TEGDMA and UDMA monomer release was obtained in LED than Halogen groups. Lower amount of monomer release was obtained in species of 30 min than 24 hrs. CONCLUSION Data has revealed that the monomer release could be detected significantly high from the composite materials polymerized by a lower output curing light device; and higher elution of monomers was determined as the composite thickness has increased. Therefore, the clinical applications of composite materials and the type of curing units have very important effects on the success of restorations and in the decrease of potential side effects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی تأثیر مواد مشابه غذا بر روی دو نوع کامپوزیت از نظر میزان آزاد شدن منومر

Background and Aims:The elution of residual monomers from cured dental composites to oral cavity has a harmful effect on human health and can affect their clinical durability. The purpose of this study was to evaluate the amount of eluted monomers (Bis-GMA, TEGDMA, UDMA) from two types of composites (Gradia and P60) after exposure to food simulating liquids such as ethanol (25, 50, 75 %) and he...

متن کامل

The evaluation of residual monomer released after polymerization of four different composite resins

Purpose: The aim of this study is to compare the amount of Bis-GMA, UDMA, and TEGDMA released from four different types of composite resins in three different time periods using the HPLC device. Materials and Methods: Four different composite resin materials with nanofiller content were used in the study. A total of 40 sample discs were prepared and polished to provide 10 pieces for each mater...

متن کامل

The effect of storage medium on the elution of monomers from composite materials.

The aim of this study was to evaluate the effect of four different storage media on the elution of monomers from two composite materials. Samples (n = 10, diameter: 4.5 mm, thickness: 2 mm) of two different composite materials (Ceram X™ & Filtek™ Supreme XT) were stored after polymerization in four different media (NaCl, saliva, ethanol 75% & acetone) for 24 h, 7 days, and 28 days. From the sto...

متن کامل

Residual HEMA and TEGDMA Release and Cytotoxicity Evaluation of Resin-Modified Glass Ionomer Cement and Compomers Cured with Different Light Sources

The purpose of this study was first to evaluate the elution of 2-hydroxyethyl methacrylate (HEMA) and triethylene glycol dimethacrylate (TEGDMA) monomers from resin-modified glass ionomer cement (RMGIC) and compomers cured with halogen and light-emitting diode (LED) light-curing units (LCUs). The effect of cured materials on the viability of L929 fibroblast cells was also evaluated. One RMGIC (...

متن کامل

Monomer Release from Resin Based Dental Materials Cured With LED and Halogen Lights

OBJECTIVES To measure the release of TEGDMA and BisGMA from two commercially available composite resins; Filtek Z 250 (3M ESPE, Germany), Leaddent (Leaddent, Germany) and two fissure sealants; Helioseal F (3M ESPE, Germany) Enamel Loc (Premiere Rev, USA) over 1, 3 and 7 days after polymerization with standard quartz-tungsten halogen Coltolux II (QHL) (Coltene Switzerland) and a standard blue li...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of paediatric dentistry : official journal of European Academy of Paediatric Dentistry

دوره 11 3  شماره 

صفحات  -

تاریخ انتشار 2010