Minimum sample frequency for multichannel intraluminal impedance measurement of the oesophagus.

نویسندگان

  • A J Bredenoord
  • B L A M Weusten
  • R Timmer
  • A J P M Smout
چکیده

In all systems for impedance monitoring signals are stored in digital format after analog-to-digital conversion at a predefined rate, the sample frequency. We aimed to find the minimum sample frequency required to evaluate oesophageal transit and gastro-oesophageal reflux studies using impedance monitoring. In 10 healthy subjects and five patients with gastro-oesophageal reflux disease impedance signals were acquired during a 90-min postprandial period, using a sample frequency of 1000 Hz. Additionally, 10 liquid swallows were recorded in the healthy subjects. A dedicated computer program was used to derive, from the original 1000-Hz files, series of new data files with sample frequencies of 500, 200, 100, 50, 20, 10, 8, 5 and 4 Hz. In all of these files, liquid and gas reflux events were identified. In the analysis of the swallows, bolus head advance time (BHAT) and total bolus transit time were measured. Reflux events were detectable down to a sample frequency of 50 Hz. In transit analysis errors for BHAT at frequencies below 8 Hz errors exceeded 2.5%. Therefore, in impedance monitoring the minimum sample frequency is 50 Hz for the detection of reflux and 8 Hz for the evaluation of oesophageal transit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of Gastroesophageal reflux disease Assessment Symptom Questionnaire to impedance-pH measurements in children

Background Esophageal multichannel intraluminal impedance-pH monitoring has become one of the preferred tests to correlate observed reflux-like behaviors with esophageal reflux events. The Gastroesophageal reflux disease Assessment Symptom Questionnaire is a validated tool used to distinguish infants with gastroesophageal reflux disease from healthy children. The aim of this study was to determ...

متن کامل

Diagnostic difficulties during combined multichannel intraluminal impedance and pH monitoring in patients with esophagitis or Barrett's esophagus.

Gastroesophageal reflux disease (GERD) is one of the most common esophageal diseases in developed countries. It is widely believed that GERD symptoms are caused by acid refluxate within the esophagus, so ambulatory 24 hour pH-monitoring became the gold standard in detecting gastroesophageal reflux. Traditional ambulatory pH monitoring is unable to detect a gastroesophageal reflux with pH >4. Th...

متن کامل

Principles of Combined Esophageal Impedance-ph Monitoring in Children: Indications, Benefits and Limitations

The standard test for suspected gastroesophageal refl ux is pH monitoring. However, the majority of gastroesophageal refl ux episodes in infants and children are nonacidic (pH > 4) and extraesophageal symptoms apparently can be caused by both acidic (pH < 4) and nonacidic refl ux. In order to overcome these aspects, a new technique has been developed and placed under scrutiny in the past twenty...

متن کامل

Combined pH-metry/impedance monitoring increases the diagnostic yield in patients with atypical gastroesophageal reflux symptoms.

BACKGROUND Globus sensations, hoarseness and chronic cough are suggested to be atypical manifestations of Gastroesophageal Reflux Disease (GERD). The aim of the study was to investigate whether combined pH-metry and multichannel intraluminal impedance monitoring increases the diagnostic yield. METHODS 41 patients with atypical GERD symptoms were included in the study. Globus sensation was the...

متن کامل

Procedure for the semi-automatic detection of gastro-oesophageal reflux patterns in intraluminal impedance measurements in infants.

The diagnosis of gastro-oesophageal reflux (GOR) is of great interest for paediatric gastroenterologists. pH monitoring is the commonly used procedure for GOR diagnosis but a major amount of postprandial GOR is missed due to the mostly non-acidic gastric contents in infants. The multiple intraluminal impedance technique is based on the recording of the impedance changes during bolus transport i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neurogastroenterology and motility : the official journal of the European Gastrointestinal Motility Society

دوره 16 6  شماره 

صفحات  -

تاریخ انتشار 2004