Gradient echo (GRASS) MR imaging in cervical radiculopathy.

نویسندگان

  • M C Hedberg
  • B P Drayer
  • R A Flom
  • J A Hodak
  • C R Bird
چکیده

Limited flip angle (LFA), gradient echo imaging was performed in 130 patients for evaluation of cervical radicular complaints. The LFA study was compared with myelography, CT myelography, and surgical results. Image quality was considered good or excellent for 128 patients. The use of a 10 degrees flip angle with a TR of 75 msec and TE of 12.3 msec consistently provided good contrast and signal-to-noise ratio, giving a CT myelographic effect. The use of both axial and sagittal LFA images was important for optimal detection of extradural defects and for distinction of herniated disk versus osteophyte. There was excellent correlation between the MR and surgical findings. Our results suggest that MR imaging is the initial procedure of choice for the evaluation of suspected cervical radiculopathy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of magnetic susceptibility artifacts and motion in evaluating the cervical neural foramina on 3DFT gradient-echo MR imaging.

The purpose of this study was to evaluate in vitro the effects of magnetic susceptibility and motion on the estimation of neural foraminal diameter with three-dimensional Fourier transformation (3DFT) gradient-recalled MR imaging as compared with CT. A cervical spine phantom was constructed from desiccated human cervical vertebral bodies embedded in a water-based proteinaceous gel. The phantom ...

متن کامل

Cervical spine: postmortem assessment of accident injuries--comparison of radiographic, MR imaging, anatomic, and pathologic findings.

PURPOSE To assess the ability of postmortem radiography and magnetic resonance (MR) imaging to depict occult cervical spine injuries as compared with anatomic and pathologic findings. MATERIALS AND METHODS The cervical spines of 10 adult accident victims underwent radiography and MR imaging, with T1-weighted, fast spin-echo T2-weighted, and four gradient-echo pulse sequences. The frozen speci...

متن کامل

Magnetic susceptibility artifacts in gradient-recalled echo MR imaging.

Artifacts related to magnetic susceptibility differences between bone and soft tissue are prevalent on gradient-recalled echo images, particularly when long echo delay times are used. These susceptibility artifacts spatially distort and artifactually enlarge bone contours. This can alter the apparent shape of the spinal canal and exaggerate the degree of spinal stenosis seen in patients with ce...

متن کامل

Cervical spondylosis: three-dimensional gradient-echo MR with magnetization transfer.

PURPOSE To compare a three-dimensional Fourier transform (3DFT) gradient-echo pulse sequence with magnetization transfer at a short echo time against standard 3DFT gradient-echo technique in the evaluation of cervical spondylosis, specifically addressing the effects of motion and susceptibility artifacts on the dimensions of the neural foramina and contrast at the cerebrospinal fluid (CSF)-spin...

متن کامل

Gradient-echo MR imaging of the cervical spine: evaluation of extradural disease.

A prospective study was undertaken on 204 consecutive patients comparing low flip angle gradient-echo and T1-weighted spin-echo techniques in the MR evaluation of cervical extradural disease. Four patient groups were studied with varying gradient-echo TEs (6 or 13 msec) and flip angles (10 degrees or 60 degrees). Images were evaluated independently for contrast behavior and anatomy, then direct...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 150 3  شماره 

صفحات  -

تاریخ انتشار 1988