Comparison of two new generation pulse oximeters with arterial oxygen saturation in critically ill children.

نویسندگان

  • Bipin Jose
  • Rakesh Lodha
  • S K Kabra
چکیده

OBJECTIVES To compare the performance of two new generation pulse oximeters, one with enhanced signal extraction technology (SET) and other without enhanced SET in detecting hypoxemia and to correlate it with arterial blood gas analysis. METHODS Forty-eight patients, admitted to pediatric intensive care unit (PICU) of a teritiary care teaching hospital in India for critical care and support during the study period, who had an arterial catheter in situ were included. Children with those disease conditions known to interfere with pulse oximetry and blood gas analysis were excluded.184 set of observations were made during the study period. Each set had oxygen saturation (SpO2) measured from both the pulse oximeters and the corresponding arterial oxygen saturation (SaO2). The values were compared for occurrence of true and false alarms during periods of normal BP, hypotension and varying degrees of hypoxia. RESULTS The mean arterial SaO2 in the study was 94.4 % ± 4.9. The mean SpO2 recorded in conventional and enhanced signal extraction technology (SET) pulse oximeters were 94.9 % ± 4.5 and 97.2 % ± 4.7 respectively. Enhanced signal extraction technology pulse oximeter detected 4/27 (15 %) of true hypoxemic events and 1 event was a false alarm. Conventional pulse oximeter detected 11/27 (41 %) true hypoxemic events but recorded 6 false alarms. CONCLUSIONS Both pulse oximeters were not found to be performing satisfactorily in picking up hypoxemia in the study. There was good correlation with mean SpO2 from pulse oximeters and arterial SaO2. The reliability of pulse oximetry decreases with worsening hypoxemia and hypotension, and the sensitivity for picking up hypoxemia can be as low as 15 %.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring carbon dioxide tension and arterial oxygen saturation by a single earlobe sensor in patients with critical illness or sleep apnea.

OBJECTIVES The purpose of the study was to evaluate a novel, combined sensor for transcutaneous monitoring of arterial oxygen saturation and carbon dioxide tension. DESIGN The new monitoring technique was compared to established reference methods. SETTING ICU and sleep laboratory of a university hospital. PATIENTS Eighteen critically ill adult patients with acute respiratory failure or he...

متن کامل

New-generation Pulse Oximetry

• OBJECTIVE To review the published, peer-reviewed studies to date on use of the new-generation pulse oximeters, which are manufactured with algorithms to filter out patients’ body motions, and describe the application of new-generation pulse oximetry in clinical practice in critical care. • METHODS MEDLINE was used to locate appropriate articles on pulse oximetry for the years 1995 to 2003. Ea...

متن کامل

Bias and precision of pulse oximeters and arterial oximeters.

We evaluated measurements of oxygen saturation from four noninvasive pulse oximeters, and two conventional arterial oximeters. Simultaneous measurements were obtained on each instrument on three different occasions in five healthy subjects breathing gas with an FIO2 of 1.00, 0.50, 0.21, 0.17, 0.15, 0.13 and 0.11. Mean bias relative to the sum of oxy-, carboxy-, and methemoglobins ranged from -0...

متن کامل

New-generation pulse oximetry in the care of critically ill patients.

OBJECTIVE To review the published, peer-reviewed studies to date on use of the new-generation pulse oximeters, which are manufactured with algorithms to filter out patients' body motions, and describe the application of new-generation pulse oximetry in clinical practice in critical care. METHODS MEDLINE was used to locate appropriate articles on pulse oximetry for the years 1995 to 2003. Each...

متن کامل

Usefulness of Pulse Oximeter That Can Measure SpO2 to One Digit After Decimal Point.

Pulse oximeters are used to noninvasively measure oxygen saturation in arterial blood (SaO2). Although arterial oxygen saturation measured by pulse oximeter (SpO2) is usually indicated in 1% increments, the value of SaO2 from arterial blood gas analysis is not an integer. We have developed a new pulse oximeter that can measure SpO2 to one digit after the decimal point. The values of SpO2 from t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Indian journal of pediatrics

دوره 81 12  شماره 

صفحات  -

تاریخ انتشار 2014