6-minute walk work for assessment of functional capacity in patients with COPD.

نویسندگان

  • Rick Carter
  • David B Holiday
  • Chiagozie Nwasuruba
  • James Stocks
  • Carol Grothues
  • Brian Tiep
چکیده

UNLABELLED The 6-min walk (6MW) test is commonly used to assess exercise capacity in patients with COPD and to track functional change resulting from disease progression or therapeutic intervention. Not surprisingly, distance covered has been the preferred outcome for this test. However, distance walked does not account for differences in body weight that are known to influence exercise capacity. OBJECTIVE The aim of this study was to evaluate the 6-min distance x body weight product (6MWORK) as an improved outcome measure with a solid physiologic foundation. PATIENTS AND METHODS One hundred twenty-four men and women with moderate-to-severe COPD volunteered and completed the testing sequence, which included pulmonary function, a peak effort ramp cardiopulmonary exercise study with gas exchange, and the 6MW. Means and SD were generated for the variables of interest. Differences were analyzed using analysis of variance techniques. Correlation coefficients and receiver operating characteristic (ROC) curves were calculated for the 6-min walk distance (6MWD) and 6MWORK with indexes of pulmonary function, work performance, and Borg scores for dyspnea and effort. RESULTS Men and women presented with a significant smoking history that also differed by gender (48 vs 66 pack-years, respectively; p < 0.01). The mean (+/- SD) FEV(1) values were 45 +/- 12.6% and 48 +/- 12.1%, respectively (not significant), while the diffusing capacity of the lung for carbon monoxide (DLCO) was 14.7 +/- 6.1 vs 10.3 +/- 3.9 mL/min/mm Hg, respectively (p < 0.001), for men and women. The 6MWD averaged 416.8 +/- 79.0 m for men and 367.8 +/- 78.6 m for women, and these differences were significant (p < 0.002). When 6MWD was compared as the percent predicted of normal values, each gender presented with a similar reduction of 78.6 +/- 14.5% vs 79.9 +/- 17.5% (p > 0.05), respectively. 6MWORK averaged 35,370 +/- 9,482 kg/m and 25,643 +/- 9,080 kg/m (p < 0.0001) for men and women, respectively. 6MWORK yielded higher correlation coefficients than did 6MWD when correlated with DLCO, lung diffusion for alveolar ventilation, FEV(1), FEV(1)/FVC ratio, watts, peak oxygen uptake, peak minute ventilation, and peak tidal volume. The ROC curve demonstrated that 6MWORK had a significantly larger calculated area under the curve (p < 0.05) [plot of 100-sensitivity to specificity for each variable of interest for all subjects] than 6MWD when differentiating an objectively selected definition of low work capacity vs high work capacity (bike ergometry work, < 55 vs > 55 W, respectively). CONCLUSIONS We conclude that work calculated as the product of distance x body weight is an improved outcome measure for the 6MW. 6MWORK can be used whenever the 6MW is required to estimate a patient's functional capacity. This measure is also a common measure, which can be converted to indexes of caloric expenditure for direct cross-modality comparisons.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A simple semipaced 3-minute chair rise test for routine exercise tolerance testing in COPD

The functional work capacity of chronic obstructive pulmonary disease (COPD) patients is usually assessed with walk tests such as the 6-minute walk test (6MWT) or the shuttle test. Because these exercise modalities require a controlled environment which limits their use by pulmonologists and severely restricts their use among general practitioners, different modalities of a short (1 minute or l...

متن کامل

Whole-body vibration improves functional capacity and quality of life in patients with severe chronic obstructive pulmonary disease (COPD): a pilot study

BACKGROUND Exercise intolerance is a common development in patients with chronic obstructive pulmonary disease (COPD). There is little data on the use of an isolated program using vibration platform training on functional capacity in these patients, which is an area that deserves investigation. AIM To investigate the effect of training on a vibrating platform (whole-body vibration [WBV]) on f...

متن کامل

Effects of Pentoxifylline on Oxygenation and Exercise Tolerance in Patients with Severe Chronic Obstructive Pulmonary Disease

Background: It was hypothesized that the use of Pentoxifylline would increase arterial O2 saturation and increase exercise tolerance in patients with Chronic Obstructive Pulmonary Disease (COPD). Methods: We tested this hypothesis in 23 patients with COPD and pulmonary hypertension. Patients were randomized to receive Pentoxifylline or placebo, each for a 12-week period, in a prospectiv...

متن کامل

Oxygen Uptake Recovery Kinetics after the 6-Minute Walk Test in Patients with Chronic Obstructive Pulmonary Disease.

BACKGROUND There is a growing interest in exercise parameters capable of objectively evaluating the functional capacity of patients with chronic obstructive pulmonary disease (COPD). OBJECTIVES The purpose of the present study was to analyze breath-by-breath cardiopulmonary and gas exchange recovery responses of patients with COPD after a 6-minute walk test (6MWT). METHODS Oxygen uptake (VO...

متن کامل

Downhill walking influence on physical condition and quality of life in patients with COPD: A randomized controlled trial

&nbsp;&nbsp;&nbsp; Background: Chronic Obstructive Pulmonary Disease (COPD), in addition to its respiratory problems, is accompanied by several musculoskeletal consequences. The aim of this study is to investigate the effectiveness of eccentric exercise in the form of downhill walking (DW) on respiratory capacity, physical function and quality of life (QOL) in patients with COPD. &nbsp;&nbsp; ...

متن کامل

Assessment of exercise capacity in African patients with chronic heart failure using six minutes walk test

BACKGROUND The purpose of this study was to assess the functional capacity during a 6-minute corridor walk and a 6-minute bicycle ergometry exercise in patients with chronic heart failure (CHF). METHOD Thirty five patients with stable CHF were recruited for the study. Each subject performed six minutes corridor walk and 6-minute bicycle ergometry testing. The 6-minute walk required the subjec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 123 5  شماره 

صفحات  -

تاریخ انتشار 2003