Measurement and monitoring of electrocardiogram belt tension in premature infants for assessment of respiratory function
نویسندگان
چکیده
BACKGROUND Monitoring of the electrocardiogram (ECG) in premature infants with conventional adhesive-backed electrodes can harm their sensitive skin. Use of an electrode belt prevents skin irritation, but the effect of belt pressure on respiratory function is unknown. A strain gauge sensor is described which measures applied belt tension. METHOD The device frame was comprised of an aluminum housing and slide to minimize the device weight. Velcro tabs connected housing and slide to opposite tabs located at the electrode belt ends. The slide was connected to a leaf spring, to which were bonded two piezoresistive transducers in a half-bridge circuit configuration. The device was tested for linearity and calibrated. The effect on infant respiratory function of constant belt tension in the normal range (30 g-90 g) was determined. RESULTS The mechanical response to a step input was second order (fn = 401 Hz, zeta = 0.08). The relationship between applied tension and output voltage was linear in the range 25-225 gm of applied tension (r2 = 0.99). Measured device sensitivity was 2.18 mV/gm tension using a 5 V bridge excitation voltage. When belt tension was increased in the normal range from 30 gm to 90 gm, there was no significant change in heart rate and most respiratory functions during monitoring. At an intermediate level of tension of 50 gm, pulmonary resistance and work of breathing significantly decreased. CONCLUSION The mechanical and electrical design of a device for monitoring electrocardiogram electrode belt tension is described. Within the typical range of application tension, cardiovascular and respiratory function are not substantially negatively affected by electrode belt force.
منابع مشابه
Analysis of Respiratory Behavior and Clinical Parameters for Successful Extubation in Premature Infants
Background The weaning process is complex and needs to be done carefully. The success of extubation in premature babies is associated with brain maturity and adequate function of the lungs. We aimed to identify the ventilator parameters and clinical conditions related to extubation success and failure in premature infants. Materials and Methods This is anobservational study, analytical and non-...
متن کاملThe effect of breast milk odor on concentration percentage of oxygen saturation and respiratory rate in premature infants
Background: establishing a regular respiratory condition in the infants is one of the basic considerations in NICU. Newborns show noticeable breath alterations in response to even low concentrations of some fragrance. Aim: determining the effect of breast milk odor on oxygen saturation and respiratory rate in premature infants. Methods: In this four-group randomized clinical trial, 180 prematu...
متن کاملNormal Value of Left Ventricular End-Systolic Elastance in Infants and Children
Background: In certain conditions, there is a need for a specific and improved measure of cardiac performance. Routine methods for assessing left ventricular (LV) function are based on image-analysis or right heart monitoring which do not allow evaluation of ventriculo-arterial interaction. Chen et al presented a noninvasive method allowing measurement of end-systolic pressure–volume relation ...
متن کاملBest Strategies against Respiratory Problems in Extremely Low Birth Weight Infants
Background Neonatology has evolved with respect to the needs of premature infants for special care. One of the major problems in premature infants is that their lungs are not developed adequately to fulfill newborns’ needs. There is a broad spectrum of strategies for management of respiratory problems in premature infants. In this study, we aimed to determine the best Strategies against Respira...
متن کاملComparison of side effect of survanta and curosurf in decreasing mortality due to respiratory distress syndrome (RDS) in premature infants admitted in NICU of Ghaem Hospital On 2006-2008
Background: Using of natural and synthetic surfactant is a rescue treatment for respiratory distress syndrome. In Iran, Survanta and Curosurf are the most frequent used natural surfactant preparations. We compared the clinical response and safety of two surfactants poractant alpha (Curosurf) and beractant (Survanta) for treatment of respiratory distress syndrome (RDS) in preterm infants. Method...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BioMedical Engineering OnLine
دوره 6 شماره
صفحات -
تاریخ انتشار 2007