Irradiance of Horizontal Quartz-Halogen Standard Lamps

نویسندگان

  • Edward A. Early
  • Ambler Thompson
چکیده

Spectral irradiance calibrations often require that irradiance standard lamps be oriented differently than the normal calibration orientation used at the National Institute of Standards and Technology and at other standards laboratories. For example, in solar measurements the instruments are generally upward viewing, requiring horizontal working standards for minimization of irradiance calibration uncertainties. To develop a working standard for use in a solar ultraviolet intercomparison, NIST determined the irradiance of quartz-halogen lamps operating in the horizontal position, rather than in the customary vertical position. An experimental technique was developed which relied upon equivalent lamps with independent mounts for each orientation and a spectroradiometer with an integrating sphere whose entrance port could be rotated 90° to view either lamp position. The results presented here are limited to 1000 W quartz-halogen type lamps at ultraviolet wavelengths from 280 nm to 400 nm. Sources of uncertainty arose from the lamps, the spectroradiometer, and the lamp alignment, and increased the uncertainty in the irradiance of horizontal lamps by less than a factor of two from that of vertical NIST standard lamps. The irradiance of horizontal lamps was less than that of vertical lamps by approximately 6 % at long wavelengths (400 nm) to as much as 12 % at the shortest wavelengths (280 nm). Using the Wien radiation law, this corresponds to color temperature differences of 15.7 K and 21.3 K for lamps with clear and frosted envelopes, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultraviolet Spectral Irradiance Scale Comparison: 210 nm to 300 nm

Comparison of the irradiances from a number of ultraviolet spectral irradiance standards, based on different physical principles, showed agreement to within their combined standard uncertainties as assigned to them by NIST. The wavelength region of the spectral irradiance comparison was from 210 nm to 300 nm. The spectral irradiance sources were: an electron storage ring, 1000 W quartz-halogen ...

متن کامل

Contributed Review: Absolute spectral radiance calibration of fiber-optic shock-temperature pyrometers using a coiled-coil irradiance standard lamp.

We describe an accurate and precise calibration procedure for multichannel optical pyrometers such as the 6-channel, 3-ns temporal resolution instrument used in the Caltech experimental geophysics laboratory. We begin with a review of calibration sources for shock temperatures in the 3000-30,000 K range. High-power, coiled tungsten halogen standards of spectral irradiance appear to be the only ...

متن کامل

The 1996 North American Interagency Intercomparison of Ultraviolet Monitoring Spectroradiometers

Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. To assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks, th...

متن کامل

Field calibration unit for ultraviolet spectroradiometers.

Horizontal standard lamps calibrate the spectral irradiance responsivity of spectroradiometers that measure solar ultraviolet irradiance. A field calibration unit and power supply developed to meet the requirements for using these standards in the field are described and their operation and associated uncertainties are detailed. Results from assessments obtained at two field instrument intercom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 101  شماره 

صفحات  -

تاریخ انتشار 1996