Reproducibility of range of motion and muscle strength measurements in patients with hip osteoarthritis – an inter-rater study
نویسندگان
چکیده
BACKGROUND Assessment of range of motion (ROM) and muscle strength is fundamental in the clinical diagnosis of hip osteoarthritis (OA) but reproducibility of these measurements has mostly involved clinicians from secondary care and has rarely reported agreement parameters. Therefore, the primary objective of the study was to determine the inter-rater reproducibility of ROM and muscle strength measurements. Furthermore, the reliability of the overall assessment of clinical hip OA was evaluated. Reporting is in accordance with proposed guidelines for the reporting of reliability and agreement studies (GRRAS). METHODS In a university hospital, four blinded raters independently examined patients with unilateral hip OA; two hospital orthopaedists independently examined 48 (24 men) patients and two primary care chiropractors examined 61 patients (29 men). ROM was measured in degrees (deg.) with a standard two-arm goniometer and muscle strength in Newton (N) using a hand-held dynamometer. Reproducibility is reported as agreement and reliability between paired raters of the same profession. Agreement is reported as limits of agreement (LoA) and reliability is reported with intraclass correlation coefficients (ICC). Reliability of the overall assessment of clinical OA is reported as weighted kappa. RESULTS Between orthopaedists, agreement for ROM ranged from LoA [-28-12 deg.] for internal rotation to [-8-13 deg.] for extension. ICC ranged between 0.53 and 0.73, highest for flexion. For muscle strength between orthopaedists, LoA ranged from [-65-47N] for external rotation to [-10 -59N] for flexion. ICC ranged between 0.52 and 0.85, highest for abduction. Between chiropractors, agreement for ROM ranged from LoA [-25-30 deg.] for internal rotation to [-13-21 deg.] for flexion. ICC ranged between 0.14 and 0.79, highest for flexion. For muscle strength between chiropractors, LoA ranged between [-80-20N] for external rotation to [-146-55N] for abduction. ICC ranged between 0.38 and 0.81, highest for flexion. Weighted kappa for the overall assessment of clinical hip OA was 0.52 between orthopaedists and 0.65 between chiropractors. CONCLUSIONS Reproducibility of goniometric and dynamometric measurements of ROM and muscle strength in patients with hip OA is poor between experienced orthopaedists and between experienced chiropractors. Orthopaedists and chiropractors can to a moderate degree differentiate between hips with or without osteoarthritis.
منابع مشابه
Intra- and Inter-Rater Reliability of Micro Manual Muscle Tester of the Lower Extremity in Children With Diplegia Cerebral Palsy
Objectives: The Micro Manual Muscle Tester (MMMT) is a Hand-Held Dynamometer (HHD). The current study aimed to evaluate the intra- and inter-rater reliability of this device. Methods: To determine the reliability of the MMMT, two previously trained assessors to work with HHD performed HHD measurements on 7 muscle groups of the lower extremities (hip flexors, hip extensors, hip abductors, knee ...
متن کاملThe Relationship Between Muscle Strength and Range of Motion in Lower Extremity, and Balance and Risk of Falling in the Elderly
Background: The present study examined the relationship between muscle strength and range of motion in the lower extremity, and balance and risk of falling in the elderly. Methods: This cross-sectional study was conducted on healthy elderly (mean±SD age: 65.64±4.95 y) in Rasht City, Iran. The study participants were 65 healthy male elderly who met the stud inclusion criteria. They were selecte...
متن کاملComparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment
Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...
متن کاملIntra-rater reliability and agreement of muscle strength, power and functional performance measures in patients with hip osteoarthritis.
OBJECTIVE To investigate the reliability and agreement of measures of lower extremity muscle strength, power and functional performance in patients with hip osteoarthritis at different time intervals, and to compare these with the same measures in healthy peers. DESIGN Intra-rater test-retest separated by 1, 2, or 2.5 weeks in patients, and 1 week in healthy peers. SUBJECTS Patients with hi...
متن کاملThe Effect of Kinesio Taping on Pain, Range of Motion, Hand Strength and Functional Abilities in Patients with Hand Osteoarthritis: A Pilot Randomized Clinical Trial
Background: Osteoarthritis is one of the most prevalent joint diseases in older adults. Since hand has a key role in daily activities, impairment of hand causes disability and reduction of independency. The present study aimed to investigate the effectiveness of kinesio taping (KT) on pain, range of motion, hand strength and functional abilities in patient with hand osteoarthritis. Method...