Iron(II)-phthalocyanine as a novel recognition sensor for selective potentiometric determination of diclofenac and warfarin drugs.

نویسندگان

  • Saad S M Hassan
  • Wagiha H Mahmoud
  • Mohamed A F Elmosallamy
  • Mahra H Almarzooqi
چکیده

Construction and characterization of potentiometric membrane sensors for quantification of diclofenac and warfarin drugs are described. The membranes of the sensors incorporate 1.8 wt.% iron(II)-phthalocyanine (Pc) as a molecular recognition reagent, 64.3 wt.% dibutylsebacate (DBS) solvent mediator, 1.8 wt.% tridodecylmethylammonium chloride (TDMAC) as membrane additive and 32.1 wt.% poly(vinyl chloride) (PVC) as a matrix. The sensors display linear response for 1 x 10(-2) to 9 x 10(-6) mol l(-1) (detection limit 5.4 x 10(-6) mol l(-1)) and 1 x 10(-2) to 5 x 10(-6) mol l(-1) (detection limit 3 x 10(-6) mol l(-1)) with anionic slopes of -61 +/- 1 and -63 +/- 1 mVdecade(-1) over the pH range 5.5-9 for declofenac and warfarin, respectively. Validation of the assay methods according to the quality assurance standards confirms their suitability for quality control purposes. Use of the sensor for the assay of various formulations of the drugs shows a mean average recovery of 99.7% of the nominal values and a mean precision of +/-0.3%. Significantly improved accuracy, precision, response time, stability, selectivity and sensitivity are offered by these simple and cost-effective potentiometric sensors compared with other standard techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Coated Graphite Potentiometric Sensor for Selective Determination of Copper (II) Ions

A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...

متن کامل

Performance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations

A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...

متن کامل

Performance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations

A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...

متن کامل

COBALT PHTHALOCYANINE MODIFIED CARBON PASTE ELECTRODE AS A POTENTIOMETRIC SENSOR FOR DETERMINATION OF ASCORBIC ACID

A carbon Paste electrode modified with cobalt (II) phthalocyanine (CoPC) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. The potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 M (?1- 1800 µg ML ) with a Nernstian slope of 56 mV at pH 7. The limit of detection was 0.2 µg ...

متن کامل

Determination of Strontium Ion in Depilatory Powder, Toothpaste, and Raticide Samples using a Novel and Highly Sensitive Potentiometric Sensor Coupled with a Central Composite Design

The strontium ion, in water-soluble forms, is one of the major pollutant in drinking water. Therefore, a simple, rapid, selective, and sensitive potentiometric carbon paste electrode was developed to measure strontium ion in real samples with complex matrices. To prepare the potentiometric sensor, a synthetic ligand ((E)-4-(((2-amino-4-chlorophenyl)imino)methyl)-5-(hydroxymethyl)-2-methyl pyrid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pharmaceutical and biomedical analysis

دوره 39 1-2  شماره 

صفحات  -

تاریخ انتشار 2005