In vitro retention of a new thermoplastic titratable mandibular advancement device
نویسندگان
چکیده
Oral appliance (OA) therapy with a mandibular advancement device (OAm) is a non-invasive, alternative approach to maintaining upper airway patency. The main requirement for an OAm to be effective is the adequate retention on the teeth while the patient is asleep. We evaluated the retentive forces of a new low-cost, customizable, titratable, thermoplastic OAm (BluePro (®); BlueSom, France). Dental impressions and casts were made for one patient with complete upper and lower dental arches including the third molars and class II bite proportions. A setup based on Frasaco ANA-4 models was also used. Two protrusive positions of the mandible were investigated: 3 mm and 8 mm, representing respectively 25% and 65% of the maximal protrusion. The forces required to remove the BluePro (®) device from the carriers were recorded continuously over 730 cycles (=365 days, twice a day) to simulate 1 year of clinical use. At 8 mm protrusion the BluePro (®) device showed retentive forces of ~27N. There was a slight but non-significant decrease in retentive forces in the tests on the epoxified carriers which was not found on the ANA-4 carriers. There were no significant differences between the carriers as a function of protrusion. The BluePro (®) device tested in the present study possesses sufficient retention forces to resist initial jaw opening forces and full mouth opening forces estimated to be ~20N. It could therefore broaden the indications for use of thermoplastic OAms. It could provide a temporary OAm while a custom-made OAm is being manufactured or repaired. Patients could be provided with a low-cost try-out device capable of reliable titration, providing an indication of effectiveness and of patient acceptance of an OAm, although the effect of device shape and size on therapeutic outcome is not yet known. Finally it could provide an affordable OAm solution in resource-restricted healthcare settings.
منابع مشابه
retention of a new thermoplastic titratable mandibular In vitro
Oral appliance (OA) therapy with a mandibular advancement device (OAm) is a non-invasive, alternative approach to maintaining upper airway patency. The main requirement for an OAm to be effective is the adequate retention on the teeth while the patient is asleep. We evaluated the retentive forces of a new low-cost, customizable, titratable, thermoplastic OAm (BluePro ; BlueSom, France). Dental ...
متن کاملOtolaryngology --head and Neck Surgery Advancement Devices'' from Friedman M Et Al Response to ''compliance and Efficacy of Titratable Thermoplastic versus Custom Mandibular on Behalf Of: American Academy of Otolaryngology-head and Neck Surgery
متن کامل
Otolaryngology office-based treatment of obstructive sleep apnea-hypopnea syndrome with titratable and nontitratable thermoplastic mandibular advancement devices.
OBJECTIVE 1) Share our experiences treating patients with obstructive sleep apnea-hypopnea syndrome (OSAHS) with titratable and nontitratable thermoplastic mandibular advancement devices (MADs) fitted in our otolaryngology clinic. 2) Compare these devices in terms of objective response (OR), as defined by a > or = 50 percent decrease in baseline apnea-hypopnea index (AHI) and an AHI < 20, and s...
متن کاملPilot Study of a New Adjustable Thermoplastic Mandibular Advancement Device for the Management of Obstructive Sleep Apnoea-Hypopnoea Syndrome: A Brief Research Letter
BACKGROUND Prefabricated adjustable thermoplastic mandibular advancement devices (PAT-MADs) are a practical short-term treatment for obstructive sleep apnoea-hypopnoea syndrome (OSAHS) in patients who have failed or refused continuous positive airway pressure (CPAP) therapy. OBJECTIVE To assess the effectiveness of a new professionally-fitted PAT-MAD in patients with OSAHS in Morocco. METHO...
متن کاملComparison of Titratable Oral Appliance and Mandibular Advancement Splint in the Treatment of Patients with Obstructive Sleep Apnea
Objective. To compare the effect of two intraoral devices (titratable oral appliance-Klearway (KW) and mandibular advancement splint (MAS)) in mild and moderate obstructive sleep apnea (OSA) patients. Method and Materials. The study group was comprised of twenty-four adult volunteer patients with OSA. Twelve subjects were fitted with a titratable oral appliance (group KW) protruding the mandibl...
متن کامل