Therapy optimization in patients with heart failure: the role of the wearable cardioverter-defibrillator in a real-world setting
نویسندگان
چکیده
BACKGROUND The wearable cardioverter-defibrillator (WCD) has emerged as a valuable tool to temporarily protect patients at risk for sudden cardiac death (SCD). The aim of this study was to determine the value of the WCD for therapy optimization of heart failure patients. METHODS One hundred five consecutive patients that received WCD between 4/2012 and 9/2016 were included in the study. All patients were followed for clinical outcome and echocardiographic parameters during WCD therapy and had continued follow-up after WCD therapy, irrespective of subsequent implantable cardioverter-defibrillator (ICD) implantation. RESULTS The most common indication for WCD were newly diagnosed ischemic (ICM) or non-ischemic cardiomyopathy (NICM) with left ventricular ejection fraction (LVEF) ≤35%. Mean WCD wear time was 68.8 ± 50.4 days with a mean daily use of 21.5 ± 3.5 h. Five patients (4.8%) received a total of five appropriate WCD shocks. During WCD wear, patients with ICM and NICM showed significant improvement in LVEF, reducing the proportion of patients with a need for primary preventive ICD implantation to 54.8% (ICM) and 48.8% (NICM). An ICD was finally implanted in 51.4% of the study patients (24 trans-venous ICDs, 30 subcutaneous ICDs). After discontinuation of WCD therapy, all patients were followed for a mean of 18.6 ± 12.3 months. 5.6% of patients with implanted ICDs received appropriate therapies. No patient with subcutaneous ICD needed change to a trans-venous device. None of the patients without an implanted ICD suffered from ventricular tachyarrhythmias and no patient died suddenly. In patients with NICM a significant LVEF improvement was observed during long-term follow-up (from 34.8 ± 11.1% to 41.0 ± 10.2%). CONCLUSIONS WCD therapy successfully bridged all patients to either LVEF recovery or ICD implantation. Following WCD, ICD implantation could be avoided in almost half of the patients. In selected patients, prolongation of WCD therapy beyond 3 months might further prevent unnecessary ICD implantation. The WCD as an external monitoring system contributed important information to optimize device selection in patients that needed ICD implantation.
منابع مشابه
THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملRisk stratification for implantable cardioverter defibrillator therapy: the role of the wearable cardioverter-defibrillator.
The benefit of implantable cardioverter-defibrillator (ICD) therapy depends upon appropriate evaluation of a persisting risk of sudden death and estimation of the patient's overall survival. Assessment of a stable and unchangeable arrhythmogenic substrate is often difficult. Structural abnormality and ventricular dysfunction, the two major risk parameters, may recover, and heart failure symptom...
متن کاملAvoiding Untimely Implantable Cardioverter/Defibrillator Implantation by Intensified Heart Failure Therapy Optimization Supported by the Wearable Cardioverter/Defibrillator—The PROLONG Study
BACKGROUND Optimal timing of implantation of an implantable cardioverter/defibrillator (ICD) after newly diagnosed heart failure is unclear given that late reverse remodelling may occur. We aimed to analyze left ventricular ejection fraction (LVEF) after diagnosis of an LVEF ≤35% during optimization of heart failure drug therapy. METHODS AND RESULTS One hundred fifty-six patients with newly d...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملThe Role of the Wearable Cardioverter- Defibrillator In Contemporary Clinical Practice
The implantable cardioverter-defibrillator (ICD) has been shown to improve survival in patients at high risk for sudden cardiac arrest (SCA). However, there remain situations in which an ICD may be inappropriate: the high risk for SCA is temporary, there is need for interruption of implanted ICD therapy (e.g. for infection), there is temporary inability to implant an ICD, there is bridge period...
متن کامل